Bryant 350MAV User Manual

Page 38

Advertising
background image

TABLE 9—MODEL 350MAV ORIFICE SIZE AND MANIFOLD PRESSURE FOR CORRECT INPUT

FOR USE WITH 140 SIZE FURNACES ONLY

(TABULATED DATA BASED ON 23,000 BTUH PER BURNER, DERATED 2% FOR EACH 1000 FT ABOVE SEA LEVEL)

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

AT ALTITUDE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

0.66

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

U.S.A.

and

Canada

850

41

3.6

41

3.7

41

3.8

40

3.6

40

3.8

875

42

3.8

41

3.5

41

3.6

41

3.7

41

3.8

900

42

3.5

42

3.7

42

3.8

41

3.5

41

3.6

0

925

42

3.4

42

3.5

42

3.6

42

3.7

42

3.8

950

42

3.2

42

3.3

42

3.4

42

3.5

42

3.6

to

975

43

3.7

43

3.8

42

3.2

42

3.3

42

3.4

1000

43

3.5

43

3.6

43

3.7

42

3.2

42

3.3

2000

1025

43

3.3

43

3.4

43

3.6

43

3.7

43

3.8

1050

43

3.2

43

3.3

43

3.4

43

3.5

43

3.6

1075

44

3.5

44

3.6

43

3.2

43

3.3

43

3.4

1100

44

3.3

44

3.4

44

3.5

43

3.2

43

3.3

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

AT ALTITUDE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

0.66

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

U.S.A.

and

Canada

U.S.A.

775

41

3.7

41

3.8

40

3.6

40

3.7

39

3.6

Altitudes

800

42

3.8

41

3.6

41

3.7

41

3.8

40

3.6

2001

825

42

3.6

42

3.7

41

3.5

41

3.6

41

3.7

to

850

42

3.4

42

3.5

42

3.6

42

3.7

41

3.5

3000

875

42

3.2

42

3.3

42

3.4

42

3.5

42

3.6

or

900

43

3.7

43

3.8

42

3.2

42

3.3

42

3.4

Canada

925

43

3.5

43

3.6

43

3.7

42

3.2

42

3.3

Altitudes

950

43

3.3

43

3.4

43

3.5

43

3.7

43

3.8

2001

975

43

3.1

43

3.3

43

3.4

43

3.5

43

3.6

to

1000

43

3.0

43

3.1

43

3.2

43

3.3

43

3.4

4500

1025

43

2.8

43

2.9

43

3.0

43

3.1

43

3.2

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

AT ALTITUDE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

0.66

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

U.S.A.

Only

750

41

3.6

41

3.8

40

3.6

40

3.7

40

3.8

775

42

3.8

41

3.5

41

3.6

41

3.7

40

3.6

800

42

3.5

42

3.7

42

3.8

41

3.5

41

3.6

3001

825

42

3.3

42

3.4

42

3.6

42

3.7

42

3.8

850

43

3.8

42

3.2

42

3.4

42

3.5

42

3.6

to

875

43

3.6

43

3.7

42

3.2

42

3.3

42

3.4

900

43

3.4

43

3.5

43

3.6

43

3.8

42

3.2

4000

925

43

3.2

43

3.3

43

3.5

43

3.6

43

3.7

950

43

3.1

43

3.2

43

3.3

43

3.4

43

3.5

975

43

2.9

43

3.0

43

3.1

43

3.2

43

3.3

1000

43

2.8

43

2.9

43

3.0

43

3.0

43

3.1

—38—

Advertising