PERFORMANCE DATA (cont)

COOLING EXTENDED PERFORMANCE TABLE

HEATING EXTENDED PERFORMANCE TABLE

-10–20

HEATING EXTENDED PERFORMANCE TABLE 30–60

*At 75°F entering dry bulb—Tennessee Valley Authority [TVA] rating conditions; all others at 80°F entering dry bulb.
See Legend and Notes on page 18.

601A030 (2.5 TONS)

Temp (F)

Air Ent

Outdoor Coil

(Edb)

Indoor Entering Air—CFM/BF

875/0.051

1000/0.077

1125/0.107

Indoor Entering Air—Ewb (F)

72

67

63*

62

72

67

63*

62

72

67

63*

62

85

TC

32.6

30.1

27.1

27.0

32.8

30.4

27.5

27.9

32.8

30.5

28.4

27.9

SHC

16.9

21.4

21.4

24.7

17.3

22.5

19.8

22.8

17.6

23.4

22.6

23.8

kW

2.79

2.73

2.63

2.60

2.89

2.84

2.68

2.76

3.02

2.96

2.91

2.87

95

TC

31.3

28.8

26.1

25.7

31.5

29.0

26.4

25.8

31.5

29.1

26.9

25.9

SHC

16.4

21.0

19.2

25.7

16.9

21.9

20.0

22.2

17.3

22.9

22.1

21.9

kW

2.97

2.92

2.84

2.78

3.08

3.03

2.85

2.87

3.21

3.15

3.07

3.03

105

TC

29.9

26.7

24.5

25.0

30.1

27.4

24.9

24.8

30.1

27.5

25.1

23.8

SHC

15.9

20.6

18.8

23.3

16.5

21.4

19.7

23.3

16.9

22.5

21.4

22.4

kW

3.17

3.05

2.97

2.98

3.28

3.20

3.20

3.19

3.41

3.30

3.21

3.17

115

TC

28.3

25.1

23.2

23.2

28.5

25.6

23.1

22.9

28.4

25.7

22.3

22.6

SHC

15.3

19.2

18.6

22.5

15.9

20.6

19.3

21.8

16.4

21.7

21.0

20.6

kW

3.36

3.24

3.15

3.11

3.48

3.36

3.22

3.32

3.61

3.47

3.31

3.54

601A030 (2.5 TONS)

Temp (F)

Indoor Air Cfm (std)

Air Temperature Entering Outdoor Coil (F db at 70% rh)

Ent Indoor Coil

-10

0

10

17

20

60

875

TC

5.66

5.20

9.42

8.65

13.15

12.07

15.63

14.24

16.91

15.23

kW

1.82

1.90

1.99

2.08

2.12

1000

TC

5.81

5.34

9.63

8.85

13.45

12.36

15.82

14.44

17.21

15.53

kW

1.86

1.94

2.02

2.11

2.15

1125

TC

5.94

5.47

9.80

9.00

13.65

12.56

16.02

14.64

17.41

15.72

kW

1.90

1.97

2.05

2.14

2.18

70

875

TC

5.02

4.63

8.74

8.03

12.46

11.47

14.83

13.55

16.12

14.54

kW

1.84

1.94

2.04

2.15

2.20

1000

TC

5.18

4.77

8.94

8.21

12.66

11.67

15.23

13.85

16.52

14.83

kW

1.88

1.98

2.08

2.18

2.23

1125

TC

5.32

4.90

9.13

8.38

12.96

11.87

15.33

13.94

16.61

15.03

kW

1.92

2.02

2.11

2.20

2.24

80

875

TC

4.28

3.95

7.96

7.31

11.67

10.68

14.14

12.86

15.33

13.85

kW

1.86

1.98

2.10

2.21

2.26

1000

TC

4.44

4.08

8.16

7.50

11.87

10.88

14.44

13.15

15.63

14.04

kW

1.90

2.02

2.13

2.24

2.29

1125

TC

4.58

4.21

8.35

7.66

12.07

11.08

14.64

13.35

15.92

14.34

kW

1.94

2.05

2.17

2.28

2.31

601A030 (2.5 TONS)

Temp (F)

Indoor Air Cfm (std)

Air Temperature Entering Outdoor Coil (F db at 70% rh)

Ent Indoor Coil

30

40

47

50

60

60

875

TC

21.26

18.69

25.91

25.91

28.58

28.58

30.86

30.86

33.13

33.13

kW

2.27

2.43

2.50

2.59

2.74

1000

TC

21.66

18.99

26.01

26.01

29.37

29.37

31.15

31.15

34.32

34.32

kW

2.30

2.44

2.53

2.60

2.81

1125

TC

21.95

19.19

26.21

26.21

29.87

29.87

31.45

31.45

35.80

35.80

kW

2.33

2.46

2.57

2.62

2.84

70

875

TC

20.27

17.70

25.22

25.22

28.38

28.38

30.26

30.26

31.84

31.84

kW

2.35

2.54

2.70

2.72

2.92

1000

TC

20.77

18.20

25.61

25.61

29.17

29.17

30.76

30.76

33.13

33.13

kW

2.37

2.56

2.68

2.74

2.94

1125

TC

21.06

18.39

25.81

25.81

29.47

29.47

31.05

31.05

34.81

34.81

kW

2.40

2.58

2.70

2.71

2.95

80

875

TC

19.28

16.91

24.13

24.13

28.38

28.38

29.77

29.77

30.86

30.86

kW

2.43

2.62

2.82

2.87

2.99

1000

TC

19.68

17.21

24.53

24.53

28.58

28.58

30.26

30.26

33.53

33.53

kW

2.46

2.65

2.81

2.88

3.05

1125

TC

19.98

17.50

24.92

24.92

28.88

28.88

30.56

30.56

34.32

34.32

kW

2.48

2.67

2.83

2.90

3.06

Advertising