Outdoor sound: octave band data - decibels, Physical data – Bryant 601A User Manual

Page 4

Advertising
background image

—4—

OUTDOOR SOUND: OCTAVE BAND DATA - DECIBELS

dB — Sound Level (decibels)

PHYSICAL DATA

* Air filter pressure drop for non-standard filters must not exceed 0.08 in. wg.

ELECTRIC HEAT PRESSURE DROP TABLES

Small Cabinet: 018-042

Large Cabinet: 048-060

MODEL NO.

601A

Frequency (Hz)

018

024

030

036

042

048

060

63

42.6

48.9

41.0

58.9

50.4

56.7

57.1

125

56.0

55.0

65.7

66.1

58.2

64.2

63.2

250

62.4

59.2

66.6

66.5

60.5

70.5

68.0

500

63.9

63.6

66.2

71.3

66.0

73.8

71.3

1000

65.4

65.6

67.7

72.9

66.8

74.0

72.3

2000

64.7

64.3

65.3

70.9

64.1

71.3

70.1

4000

62.6

63.5

62.1

66.1

61.8

68.9

67.4

8000

54.4

57.7

56.2

58.6

53.0

60.9

61.0

UNIT SIZE 601A

018

024

030

036

042

048

060

NOMINAL CAPACITY (ton)

1-1/2

2

2-1/2

2-1/2

3-1/2

4

5

OPERATING WEIGHT (lb)

283

289

287

291

323

353

418

COMPRESSORS

1

Quantity

1

TYPE

RECIPROCATING COMPRESSOR

SCROLL COMPRESSOR

REFRIGERANT*

R-22

REFRIGERANT METERING DEVICE

Accurater

Refrigerant (R-22) Quantity (lb.)

6.5

5.3

5.6

7.6

8.0

7.85

9.3

ORIFICE ID (in.)

0.053

0.061

0.068

0.078

0.078

0.088

0.093

ORIFICE ID (in.)

0.040

[email protected]

[email protected]

[email protected]

[email protected]

[email protected]

[email protected]

OUTDOOR COIL

Rows—Fins/in.
Face Area (sq ft)

1—17

10.2

1—17

12.0

1—17

12.0

2—17

10.3

2—17

10.3

2—17

11.6

2—17

11.6

OUTDOOR FAN

Nominal Airflow (Cfm)
Diameter
Motor Hp (Rpm)

2400

22

1/8 (825)

2400

22

1/8 (825)

2400

22

1/8 (825)

2800

22

1/4 (1100)

2400

22

1/8 (825)

3300

22

1/4 (1100)

3300

22

1/4 (1100)

INDOOR COIL

Rows—Fins/in.
Face Area (sq ft)

2—15

3.7

2—15

3.7

3—15

3.7

3—15

3.7

4—15

3.7

3—15

4.7

4—15

4.7

INDOOR BLOWER

Nominal Airflow (Cfm)
Size (in.)
Motor Hp (Rpm)

700

10 x 10

1/4 (825)

800

10 x 10

1/4 (1050)

1000

10 x 10

1/4 (1050)

1200

11 x 10

1/2 (1075)

1250

11 x 10

3/4 (1075)

1600

11 x 10

3/4 (1075)

2000

11 x 10

1 (1100)

RETURN-AIR FILTERS (In.)*

Throwaway

20 x 20 x 1

20 x 20 x 1

20 x 20 x 1

20 x 24 x 1

24 x 30 x 1

24 x 30 x 1

24 x 30 x 1

STATIC

CFM

500

600

700

800

900

1000

1100

1200

1300

1400

1500

1600

5 Kw

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.02

0.04

0.06

0.07

10 Kw

0.00

0.00

0.00

0.00

0.00

0.02

0.04

0.06

0.07

0.09

0.10

0.11

15 Kw

0.00

0.00

0.00

0.02

0.04

0.06

0.08

0.10

0.12

0.14

0.16

0.18

20 Kw

0.00

0.00

0.02

0.04

0.06

0.08

0.09

0.11

0.13

0.15

0.17

0.19

STATIC

CFM

1100

1200

1300

1400

1500

1600

1700

1800

1900

2000

2100

2200

2300

2400

2500

5 Kw

0.00

0.00

0.00

0.01

0.02

0.03

0.04

0.05

0.06

0.07

0.08

0.09

0.10

0.11

0.12

10 Kw

0.00

0.00

0.01

0.02

0.03

0.04

0.05

0.06

0.07

0.08

0.09

0.10

0.11

0.12

0.13

15 Kw

0.00

0.02

0.03

0.04

0.05

0.06

0.07

0.08

0.09

0.10

0.11

0.12

0.13

0.14

0.15

20 Kw

0.02

0.03

0.04

0.05

0.06

0.07

0.08

0.09

0.10

0.11

0.12

0.13

0.14

0.15

0.16

3 2

5

A2

M

A

N

U

F

A

C

T

U

R

E

R

CE

RT

IFIED

TO ARI

AS

C

O

M

P

L

Y

IN

G
W

IT

H

A

RI

STANDARD

24

0

U

N

IT

A

R

Y

HE

A

T

P

U

M

P

EQUIPMENT

®

Advertising