PERFORMANCE DATA (cont)

COOLING EXTENDED PERFORMANCE TABLE

HEATING EXTENDED PERFORMANCE TABLE

-10–20

HEATING EXTENDED PERFORMANCE TABLE 30–60

*At 75°F entering dry bulb—Tennessee Valley Authority [TVA] rating conditions; all others at 80°F entering dry bulb.
See Legend and Notes on page 18.

601A036 (3 TONS)

Temp (F)

Air Ent

Outdoor Coil

(Edb)

Indoor Entering Air—CFM/BF

1050/0.10

1200/0.13

1350/0.17

Indoor Entering Air—Ewb (F)

72

67

63*

62

72

67

63*

62

72

67

63*

62

85

TC

39.4

36.0

33.2

32.3

39.5

36.6

33.9

33.1

40.0

37.1

34.2

33.7

SHC

19.3

24.5

23.7

29.1

19.8

25.9

25.0

30.9

20.4

27.2

26.3

32.4

kW

3.43

3.38

3.29

3.31

3.50

3.45

3.38

3.40

3.58

3.54

3.45

3.48

95

TC

38.1

34.3

31.6

30.7

38.5

35.0

32.2

31.5

39.1

35.5

32.6

32.1

SHC

18.9

23.9

23.0

28.3

19.6

25.3

24.4

30.1

20.4

26.8

25.7

31.6

kW

3.67

3.59

3.48

3.50

3.75

3.68

3.58

3.60

3.83

3.77

3.65

3.68

105

TC

36.4

32.6

30.0

29.1

36.9

33.2

30.5

29.8

37.5

33.6

30.7

30.5

SHC

18.3

23.2

22.4

27.5

19.0

24.7

23.8

29.1

19.9

26.0

24.9

30.4

kW

3.91

3.80

3.69

3.69

3.99

3.89

3.78

3.79

4.07

3.98

3.85

3.89

115

TC

34.5

30.8

28.2

27.3

35.1

31.3

28.5

28.2

35.5

31.7

28.9

29.1

SHC

17.6

22.5

21.6

26.6

18.5

24.0

23.0

28.2

19.2

25.4

24.3

29.1

kW

4.13

4.01

3.88

3.90

4.23

4.11

3.98

4.01

4.31

4.19

4.06

4.10

601A036 (3 TONS)

Temp (F)

Indoor Air Cfm (std)

Air Temperature Entering Outdoor Coil (F db at 70% rh)

Ent Indoor Coil

-10

0

10

17

20

60

1050

TC

6.06

5.61

11.03

10.20

15.93

15.06

19.38

17.65

20.91

18.80

kW

2.28

2.45

2.61

2.72

2.77

1200

TC

6.26

5.79

11.32

10.47

16.31

15.40

19.86

18.13

21.35

19.24

kW

2.35

2.50

2.66

2.76

2.82

1350

TC

6.46

5.97

11.61

10.74

16.69

15.73

20.24

18.42

21.78

19.67

kW

2.41

2.56

2.71

2.81

2.86

70

1050

TC

5.28

4.88

10.07

9.32

14.87

14.01

18.23

16.60

19.67

17.75

kW

2.29

2.48

2.67

2.79

2.85

1200

TC

5.52

5.10

10.41

9.63

15.25

14.39

18.71

17.08

20.10

18.13

kW

2.36

2.53

2.72

2.84

2.89

1350

TC

5.76

5.32

10.75

9.94

15.64

14.77

19.09

17.37

20.53

18.52

kW

2.42

2.59

2.76

2.89

2.94

80

1050

TC

4.14

3.83

8.90

8.23

13.62

12.86

16.98

15.45

18.42

16.89

kW

2.28

2.49

2.71

2.86

2.93

1200

TC

4.46

4.12

9.25

8.55

14.06

13.24

17.65

16.12

18.85

17.13

kW

2.35

2.55

2.76

2,90

2.97

1350

TC

4.77

4.41

9.59

8.87

14.49

13.62

17.84

16.31

19.28

17.37

kW

2.42

2.61

2.81

2.95

3.01

601A036 (3 TONS)

Temp (F)

Indoor Air Cfm (std)

Air Temperature Entering Outdoor Coil (F db at 70% rh)

Ent Indoor Coil

30

40

47

50

60

60

1050

TC

25.81

22.64

31.37

31.37

35.98

35.98

37.42

37.42

41.73

41.73

kW

2.94

3.12

3.28

3.31

3.43

1200

TC

26.58

23.22

31.95

31.95

36.55

36.55

37.61

37.61

42.31

42.31

kW

2.96

3.15

3.29

3.33

3.46

1350

TC

26.86

23.60

32.43

32.43

36.65

36.65

37.70

37.70

43.08

43.08

kW

3.01

3.18

3.30

3.33

3.51

70

1050

TC

24.46

21.39

29.93

29.93

34.54

34.54

36.07

36.07

41.54

41.54

kW

3.04

3.24

3.42

3.47

3.66

1200

TC

24.85

21.87

30.51

30.51

35.21

35.21

36.75

36.75

42.02

42.02

kW

3.06

3.26

3.43

3.49

3.66

1350

TC

25.52

22.35

31.08

31.08

35.79

35.79

36.75

36.75

42.12

42.12

kW

3.11

3.30

3.46

3.48

3.69

80

1050

TC

23.22

20.34

28.40

28.40

33.00

33.00

34.54

34.54

41.35

41.35

kW

3.14

3.36

3.55

3.61

3.90

1200

TC

23.89

20.82

29.17

29.17

33.67

33.67

35.21

35.21

41.54

41.54

kW

3.18

3.38

3.57

3.63

3.90

1350

TC

24.18

21.20

29.74

29.74

34.25

34.25

35.88

35.88

41.73

41.73

kW

3.21

3.42

3.60

3.66

3.90

Advertising