Performance data (cont) – Bryant 601A User Manual

Page 16

Advertising
background image

—16—

PERFORMANCE DATA (cont)

COOLING EXTENDED PERFORMANCE TABLE

HEATING EXTENDED PERFORMANCE TABLE

-10–20

HEATING EXTENDED PERFORMANCE TABLE 30–60

*At 75°F entering dry bulb—Tennessee Valley Authority [TVA] rating conditions; all others at 80°F entering dry bulb.
See Legend and Notes on page 18.

601A048 (4 TONS)

Temp (F)

Air Ent

Outdoor Coil

(Edb)

Indoor Entering Air—CFM/BF

1400

1600

1800

Indoor Entering Air—Ewb (F)

72

67

63*

62

72

67

63*

62

72

67

63*

62

85

TC

51.8

48.6

45.1

44.4

51.8

48.8

45.5

45.5

51.9

48.8

46.6

46.3

SHC

26.7

34.5

33.3

41.6

27.1

36.0

34.9

44.5

27.4

37.2

37.3

46.3

kW

4.20

4.19

4.17

4.11

4.36

4.35

4.34

4.21

4.55

4.54

4.54

4.34

95

TC

50.8

46.7

43.0

42.1

50.8

47.0

43.4

43.5

50.9

47.0

45.5

44.8

SHC

26.5

33.8

32.2

40.0

27.0

35.4

33.8

43.5

27.4

36.8

36.4

44.8

kW

4.58

4.57

4.55

4.45

4.75

4.74

4.73

4.59

4.95

4.93

4.89

4.71

105

TC

49.0

44.7

40.9

40.3

49.1

44.7

41.3

41.5

49.2

45.0

43.3

42.7

SHC

25.9

33.1

31.2

39.1

26.5

34.4

32.9

41.5

27.0

36.2

36.4

42.7

kW

5.00

5.02

4.92

4.81

5.16

5.15

5.11

4.94

5.35

5.31

5.27

5.13

115

TC

47.1

42.1

38.8

37.3

47.3

42.4

41.6

39.9

47.4

42.8

42.5

40.7

SHC

25.2

31.7

32.2

37.3

25.7

33.5

35.7

39.9

26.3

35.6

37.7

40.7

kW

5.47

5.41

5.33

5.29

5.61

5.57

5.41

5.33

5.80

5.75

5.56

5.54

601A048 (4 TONS)

Temp (F)

Indoor Air Cfm (std)

Air Temperature Entering Outdoor Coil (F db at 70% rh)

Ent Indoor Coil

-10

0

10

17

20

60

1400

TC

16.34

13.83

20.69

17.60

25.04

23.01

28.43

25.91

30.26

27.27

kW

3.22

3.34

3.44

3.52

3.57

1600

TC

16.63

14.12

20.98

17.89

25.43

23.30

28.81

26.30

30.55

27.56

kW

3.27

3.36

3.47

3.55

3.59

1800

TC

16.82

14.31

21.27

18.08

25.72

23.59

29.10

26.59

30.94

27.94

kW

3.31

3.41

3.51

3.59

3.63

70

1400

TC

15.57

13.25

20.02

17.02

24.46

22.43

27.85

25.43

29.49

26.59

kW

3.45

3.57

3.68

3.78

3.83

1600

TC

15.86

13.54

20.31

17.31

24.85

22.82

28.23

25.72

29.97

27.07

kW

3.50

3.61

3.71

3.80

3.85

1800

TC

16.15

13.73

20.69

17.60

25.14

23.11

28.52

26.01

30.36

27.36

kW

3.55

3.65

3.74

3.83

3.88

80

1400

TC

14.70

12.47

19.24

16.34

23.69

21.76

27.17

24.75

28.81

26.01

kW

3.68

3.82

3.95

4.05

4.11

1600

TC

14.99

12.76

19.53

16.63

24.08

22.14

27.56

25.14

29.20

26.30

kW

3.73

3.85

3.97

4.07

4.12

1800

TC

15.28

13.05

19.82

16.92

24.46

22.43

27.94

25.43

29.59

26.69

kW

3.78

3.89

4.00

4.10

4.14

601A048 (4 TONS)

Temp (F)

Indoor Air Cfm (std)

Air Temperature Entering Outdoor Coil (F db at 70% rh)

Ent Indoor Coil

30

40

47

50

60

60

1400

TC

36.16

31.71

42.54

42.54

47.67

47.67

48.25

48.25

53.95

53.95

kW

3.72

3.90

4.03

3.99

4.11

1600

TC

36.55

32.00

43.03

43.03

47.77

47.77

49.31

49.31

54.53

54.53

kW

3.72

3.89

4.01

4.03

4.15

1800

TC

36.94

32.39

43.03

43.03

47.96

47.96

49.41

49.41

55.79

55.79

kW

3.75

3.89

4.00

4.08

4.24

70

1400

TC

35.10

30.75

41.67

41.67

47.09

47.09

48.15

4815

53.66

53.66

kW

3.98

4.17

4.36

4.41

4.46

1600

TC

35.87

31.42

42.16

42.16

47.28

47.28

49.02

49.02

54.34

54.34

kW

3.99

4.17

4.31

4.35

4.52

1800

TC

36.26

31.71

42.54

42.54

47.67

47.67

49.12

48.83

54.63

54.63

kW

4.01

4.18

4.31

4.45

4.46

80

1400

TC

34.33

30.07

40.80

40.80

46.12

46.12

47.86

47.86

53.18

53.18

kW

4.28

4.49

4.69

4.75

4.97

1600

TC

34.71

30.46

41.29

41.29

46.61

46.61

48.35

48.35

54.24

54.24

kW

4.28

4.47

4.66

4.70

4.91

1800

TC

35.10

30.75

41.67

41.67

47.09

47.09

48.44

48.44

54.44

54.44

kW

4.29

4.47

4.64

4.67

4.83

Advertising