Section 3 preventive maintenance, After each use, Weekly – Hale 4DK Series User Manual

Page 15: Monthly, Annually, Gear box - oil change, Figure 5: recommended oils, Figure 6: sight level gauge/lubrication, After each use weekly monthly annually, Gear box – oil change

Advertising
background image

Manual p/n: 029-0020-79-0

15

4DK Series Pumps

SECTION 3 PREVENTIVE MAINTENANCE

For climates with ambient temperatures below
freezing (32°F/0°C), use Dextron III synthetic
oil (Cognis 2803 or equal).

An oil level sight gauge is provided on the
side of the gear box. (See Figure 6: "Sight
Level Gauge/Lubrication.") The gear box
requires five (5) quarts (4.7liters) of oil to
bring the level to the halfway point on the
sight level gauge (minimum FULL level).
Adding oil in excess of the halfway point may
cause the unit to run in excess of higher than
recommended operating temperature.

AFTER EACH USE

Check seals for leaks.

Check piping for leaks.

Close all valves and caps.

WEEKLY

Verify operation of pump shift indicator.

Check drive lines.

MONTHLY

Check drive lines and flange bolts to ensure:

No bolts are missing.

All bolts are tight.

Bolts used are “Grade 8” strength.

Check pump mounting bolts to ensure

No bolts missing.

All bolts are tight.

ANNUALLY

Gear Box – Oil Change

Replace gearbox oil with recommended type.
See Figure 5: "Recommended Oils Chart"
and in the next column.

For climates with ambient temperatures
above -5°F (-15°C) replace then gearbox oil
with Emgard SAE 50 synthetic oil (Cognis
2924/2833 or equal).

Figure 5: Recommended Oils

Note: Use above specified lubricants or equal.
Consult factory for additional recommendations.

4DK AMBIENT TEMPERATURE OIL SELECTION

DEXRON III
SYNTHETIC
COGNIS 2803

EMGARD SAE 50
SYNTHETIC
COGNIS 294 / 2833

-40 -30 -20 -10

0

-5

10 20

30 40 60

80 100 120

5

°F

Minimum FULL Level

Oil Level Sight Gauge

Oil Fill Plug

Speed Counter Grease

Fitting

Figure 6: Sight Level Gauge/ Lubrication

Advertising