Figure 23: maximum recommended driveline lengths, Plumbing connections, 4dk pump – Hale 4DK Series User Manual

Page 42: 4dk6 pump, 4dk pump 4dk6 pump

Advertising
background image

42

Manual p/n: 029-0020-79-0

4DK Series Pumps

Suspension travel and torque wrap-up can
change a marginal driveline into one that is
unacceptable.
Always consider the full movement of the
driveline.

Center your driveline sliders and ensure they
have sufficient travel to allow for the entire
movement of the suspension.

Do not measure driveline angles using a
bubble protractor. Instead, use a digital
inclinometer.
Remember to zero the inclinometer on the
truck frame, not the ground.

Spilt-shaft drivelines inherently have yoke
phasing that can change with every shift.
This is one reason to design the other
aspects of the driveline more conserv-atively
than a "non-split shaft" truck driveline.

Long drivelines can lead to component vibration
or failure. As the driveline approaches half
critical speed, a vibration will occur that can
damage driveline components.

Figure 23: "Maximum Recommended Drive
Lengths," in the next column, lists the maximum
driveline length using a safety factor of 42% of
critical speed. This table is based on a 0.134”
(3.4mm) wall thickness. Although wall thickness
does not have a significant effect on drive shaft
length for this calculation, it does have some
effect.

Extremely short drive lengths between the pump
and the rear axle can also cause problems from
excessive operating angles when the suspension
articulates. Use caution and conservative design
values when utilizing air ride suspension and
short rear drivelines.

More information on fire apparatus drivelines can
be found in Hale OEM Technical Bulletin # 957.
For application assistance and approval, contact
a driveline equipment manufacturer, such as
Spicer/Dana or Merritor.

Shaft

2.0

2.5

3.0

3.5

4.0

4.5

RPM

2400

47

53

58

63

67

71

2600

45

51

55

60

64

68

2800

44

49

53

58

62

65

3000

42

47

52

56

60

63

3200

41

46

50

54

58

61

3400

39

44

48

53

56

69

3600

38

43

47

51

55

58

3800

37

42

46

50

53

56

4000

36

41

45

48

52

55

Figure 23: Maximum Recommended Driveline Lengths

Driveline tube size (diameter) in inches

PLUMBING CONNECTIONS

4DK Pump

The 4DK pump is provided with a 4” Victaulic
suction connection and a 4” Victaulic opposite-
suction-side discharge connection.

An optional 4” Victaulic suction-side discharge
connection is also available.

4DK6 Pump

The 4DK6 pump is provided with a 6” Victaulic
suction connection and a 4” Victaulic opposite-
suction-side discharge connection.

An optional 4” Victaulic suction-side discharge
connection is also available.