29/04/08 Page 6 of 13 3786407

17. Remove the cover from the control
box.

18. The three main power cables that go
from winch to control box, must be
changed over using longer cables from
bolt kit. Make sure that you identify the
colour codes on the new cables before
replacing the cover.

(This must be done for all winches to be

fitted to the bull bar)

If fitting XP 9.5 winch, leave

cover open and continue to step
19. For any other winch,
advance to step 25.

19. For

XP 9.5 winch

, remove the two

cap screws, nuts and spacer washers that
hold the four solenoids in place.

Advertising