Monitoring controller status – Apple Xsan 1.4 User Manual

Page 130

Advertising
background image

130

Chapter 5

Managing Metadata Controllers

To upgrade controller software without interruption:

1

Switch all volumes to a standby controller.

Go to the primary controller, open Terminal, and type:

$ sudo cvadmin -e ”fail volume“

where

volume

is the name of an Xsan volume.

To see a list of volumes hosted by the controller, type:

$ sudo cvadmin -e select

To see which controller is hosting a volume, open Xsan Admin, select the volume, and

click Overview.

2

When all volumes are being hosted by the standby controller, upgrade the software on

the primary controller.

3

When you are finished upgrading the primary controller, use the methods in step 1 to

switch control of active volumes back to the primary controller.

Now you can upgrade the standby controller.

Monitoring Controller Status

For information about checking or reporting the status of a controller, see these topics:

 “Viewing a Controller’s CPU and Network Utilization” on page 136

 “Setting Up Status Notifications” on page 138

 “Checking the Status of File System Processes” on page 139

 “Viewing Xsan Logs” on page 139