Lull 944E-42 Service Manual User Manual

Page 202

Advertising
background image

Electrical System

9-44

944E-42

527

702

3

Amber

Circuit - Voltage

Auxiliary Input/Output 2 Circuit - Voltage Above
Normal, or Shorted to High Source

528

93

2

Amber

Switch - Data

Auxiliary Alternate Torque Validation Switch -
Data Erratic, Intermittent, or Incorrect

529

703

3

Amber

Circuit - Voltage

Auxiliary Input/Output 3 Circuit - Voltage Above
Normal, or Shorted to High Source

546

94

3

Amber

Fuel Delivery

Pressure

Fuel Delivery Pressure Sensor Circuit - Voltage
Above Normal, or Shorted to High Source

547

94

4

Amber

Fuel Delivery

Pressure

Fuel Delivery Pressure Sensor Circuit - Voltage
Below Normal, or Shorted to Low Source

551

558

4

Amber

Accelerator Pedal

Low Idle Switch

Accelerator Pedal or Lever Idle Validation
Circuit - Voltage Below Normal, or Shorted to
Low Source

553

157

16

Amber

Injector Metering

Rail 1 Pressure

Injector Metering Rail #1 Pressure High - Data
Valid but Above Normal Operational Range -
Moderately Severe Level

554

157

2

Amber

Injector Metering

Rail 1 Pressure

Fuel Pressure Sensor Error - Data Erratic,
Intermittent, or Incorrect

559

157

18

Amber

Injector Metering

Rail 1 Pressure

Injector Metering Rail #1 Pressure Low - Data
Valid but Below Normal Operational Range -
Moderately Severe Level

584

677

3

Amber

Starter Solenoid

Lockout Relay Driver

Circuit

Starter Relay Circuit - Voltage Above Normal, or
Shorted to High Source

585

677

4

Amber

Starter Solenoid

Lockout Relay Driver

Circuit

Starter Relay Circuit - Voltage Below Normal, or
Shorted to Low Source

595

103

16

Amber

Turbocharger 1

Speed

Turbocharger #1 Speed High - Data Valid but
Above Normal Operational Range - Moderately
Severe Level

596

167

16

Amber

Alternate Potential

(voltage)

Electrical Charging System Voltage High - Data
Valid but Above Normal Operational Range -
Moderately Severe Level

597

167

18

Amber

Alternate Potential

(voltage)

Electrical Charging System Voltage Low - Data
Valid but Below Normal Operational Range -
Moderately Severe Level

598

167

1

Red

Alternate Potential

(voltage)

Electrical Charging System Voltage Low - Data
Valid but Below Normal Operational Range -
Most Severe Level

Fault

Codes

SPN

Codes

FMI

Codes

Lamp

Color

SPN Description

Cummins Description