Stabil-trak, Electrical circuit operation and troubleshooting, Stabil-trak™ system – Lull 944E-42 Service Manual User Manual

Page 216

Advertising
background image

Stabil-TRAK™ System

10-4

944E-42

10.3

STABIL-TRAK™

ELECTRICAL CIRCUIT OPERATION AND TROUBLESHOOTING

Note: Before using the 944E Stabil-TRAK System
Troubleshooting chart and diagrams, complete the
Section 10.4, “Stabil-TRAK™

System Test”, to determine

what part of the system is not functioning properly.

Definitions:
PB = Park Brake

SB = Service Brake

DE = De-energized

E = Energized

C = Closed

O = Open

Stabil-TRAK™

System

Troubleshooting

FREE PIVOT

MODE

SLOW PIVOT

MODE

LOCKED

MODE I

LOCKED

MODE II

LOCKED

MODE III

Machine

Conditions

Switch/
Relay
Solenoid

Ignition On.

Boom Below 40°.

PB “OFF” &

SB Released.

Transmission

Fwd. or Rev.

Ignition On.

Boom Above 40°.

PB “OFF” &

SB Released.

Transmission

Fwd. or Rev.

Ignition On.

Boom Above 40°.

PB “ON” &

SB Released.

Transmission

Neutral.

Ignition On.

Boom Above 40°.

* PB “OFF” &

SB Applied.

Transmission

Fwd. or Rev.

Ignition On.

Boom Above 40°.

PB “OFF” &

SB Released.

Transmission

Neutral.

Solenoid 12A

E

DE

DE

DE

DE

Solenoid 12B

E

DE

DE

DE

DE

Solenoid 3

DE

DE

E

E

E

Solenoid 4A

DE

E

DE

DE

DE

Solenoid 4B

DE

E

DE

DE

DE

Boom Proximity Sensor

C

O

O

O

O

Boom Switch Relay (E7)

E

DE

DE

DE

DE

Stabilizer Lock Relay (E6)

DE

DE

E

E

E

Stabilizer Lock Mode Light

OFF (DE)

OFF (DE)

ON (E)

ON (E)

ON (E)

Stabilizer Slow Pivot Mode
Light

OFF (DE)

ON (E)

OFF (DE)

OFF (DE)

OFF (DE)

Neutral Start Relay (E3)

DE

DE

DE

DE

E

Park Brake Solenoid

E

E

DE

E

E

Park Brake Switch

O

O

C

O

O

Stabilizer Brake Switch

O

O

O

C

O

Transmission Control
Relay (E1)

DE

DE

E

DE

DE

Advertising