SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
3121627
– JLG Lift –
6-27
Installation
BE SURE TO REINSTALL THE FILTER MAGNET INTO THE HOUSING BEFORE INSTALLING
NEW SEAL
1.
Install the mounting plate to lock off O-ring seal.
2.
If equipped, install the retaining bolt seal.
3.
Install the housing seal.
4.
Drop the magnet into the bottom of the filter housing.
5.
Install the filter into the housing.
6.
If equipped, install the retaining bolt into the filter housing.
7.
Install the filter up to the bottom of the electric lock off.
8.
Tighten the filter bowl retainer to 106 in lbs (12 Nm).
9.
Open manual shut-off valve. Start the vehicle and leak check
the propane fuel system at each serviced fitting. Refer to
Propane Fuel System Leak Test.
1.
Electric Lock Off Solenoid
2.
Housing Seal
3.
Filter Magnet
4.
Filter Housing
5.
Electrical Connector
6.
Fuel Outlet
7.
O-ring
8.
Filter
9.
Fuel Inlet
10. Ring
Figure 6-7. Filter Lock Assembly