DISCONTINUE OPERATION IF PLUNGER IS NOT FULLY EXTENDED

b. Attempt to extend the tower fly boom. The tower fly

boom should not extend and the red boom malfunc-
tion light in the ground control panel should illuminate
when pressing the tower telescope switch.

DISCONTINUE OPERATION IF THE TOWER FLY BOOM EXTENDS OR THE BOOM MAL-
FUNCTION LIGHT DOES NOT ILLUMINATE.

c. Raise the tower base boom to approximately 40

degrees, then lower the tower boom back to the below
horizontal position. While raising and lowering the
tower boom assembly, observe the position of the
upright. Ensure that the upright remains vertical rela-
tive to the chassis. Refer to Figure 2-7. and Figure 2-8.

DISCONTINUE OPERATION IF THE UPRIGHT IS OUT OF ALIGNMENT OR THE BOOM
MALFUNCTION LIGHT IS FLASHING OR ON STEADY.

d. Raise the tower base boom to full height. Extend the

tower fly boom a few feet. Check that the plunger on

the tower boom horizontal limit switch at the end of
the tower base boom section is fully extended. The
plunger is shown fully extended in Figure 2-6.