4 traveling (driving), Traveling (driving) -7 – JLG 800A_AJ Operator Manual User Manual

Page 71

Advertising
background image

SECTION 4 - MACHINE OPERATION

3121627

– JLG Lift –

4-7

• Engine Restart - When the engine shuts down, the opera-

tor will be permitted to cycle power and restart the engine
for approximately 2 minutes of run time. After the 2 min-
utes of run time is complete, the operator may cycle power
and restart the engine for an additional 2 minutes of run
time. The operator can repeat this process until there is no
more fuel available.

CONTACT A QUALIFIED JLG MECHANIC IF THE MACHINE NEEDS RESTARTED AFTER NO
MORE FUEL IS AVAILABLE.

• Engine Stop - When the engine shuts down, no restarts

will be permitted until fuel is added to the tank.

4.4

TRAVELING (DRIVING)

See Figure 4-4., Grade and Sideslopes

NOTE:

Refer to the Operating Specifications table for Gradeability and
Sideslope ratings.

All ratings for Gradeability and Sideslope are based upon the
machine’s boom being in the stowed position, fully lowered, and
retracted.

Traveling is limited by two factors:

1.

Gradeability, which is the percent of grade of the incline the
machine can climb.

2.

Sideslope, which is the angle of the slope the machine can
be driven across.

Advertising