3 pre-start inspection, 4 daily walk-around inspection, Pre-start inspection -3 – JLG DVSP Series Operator Manual User Manual

Page 17: Daily walk-around inspection -3

Advertising
background image

SECTION 2 - PREPARATION AND INSPECTION

3121135

– JLG Lift –

2-3

2.3 PRE-START INSPECTION

The Pre-Start Inspection should include each of the follow-
ing:

1.

Cleanliness – Check all surfaces for leakage (oil,
fuel, or battery fluid) or foreign objects. Report any
leakage to the proper maintenance personnel.

2.

Decals and Placards – Check all for cleanliness
and legibility. Make sure no decals or placards are
missing. Make sure all illegible decals and placards
are cleaned or replaced. (Reference "Decal Installa-
tions" in Section 3)
.

3.

Operators and Safety Manuals – Make sure a copy
of the Operator and Safety Manual, EMI Safety Man-
ual (Domestic only), and ANSI Manual of Responsi-
bilities (Domestic only) is enclosed in the weather
resistant storage container.

4.

Daily Walk-Around Inspection(See Section 2.4)

5.

Battery – Charge as required.

6.

Hydraulic Oil – Check the hydraulic oil level.

NOTE: Check Service Manual for instructions and hydraulic

oil specification before adding. DO NOT OVERFILL.

7.

Function Check – Check all machine controls for
operation. (See Section 2.5)

If optional equipment is installed on this machine refer to
Section 3 for specific Pre-Start Inspection and Operation
instructions.

2.4 DAILY WALK-AROUND INSPECTION

Begin the “Walk-Around Inspection” at item one (1) as
noted on the diagram. Continue around machine check
each item in sequence for the conditions listed in the fol-
lowing check list.

TO AVOID POSSIBLE INJURY, BE SURE MACHINE POWER IS
“OFF” DURING “WALK-AROUND INSPECTION”.

DO NOT OPERATE MACHINE UNTIL ALL MALFUNCTIONS HAVE
BEEN CORRECTED.

IMPORTANT

DO NOT OVERLOOK VISUAL INSPECTION OF THE BASE FRAME
UNDERSIDE. CHECK THIS AREA FOR OBJECTS OR DEBRIS
WHICH COULD CAUSE EXTENSIVE MACHINE DAMAGE.

NOTE: On all components, make sure there are no loose or

missing parts, that they are securely fastened, and
that no visible damage, leaks or excessive wear
exists in addition to any other criteria mentioned.

1.

Drive and Caster Wheels - Check for any debris
stuck to or around wheels.

2.

Base Frame - Check pot-hole-protection system
components; check for loose wires or cables dan-
gling below the base.

3.

Manual Descent Control Valve - See note above.

4.

Motor/Pump/Reservoir Unit - No evidence of
hydraulic leaks. Hydraulic oil level should be filled
level with the full line.

5.

Batteries - Battery cables; no corrosion.

6.

Platform Assembly and Gate - Quick-Change plat-
form mounting and mounting pins; DVSP - platform
fasteners; platform railings; entry bar or gate in
proper working order.

7.

Platform Control Console - Platform control; plac-
ards secure and legible; emergency stop switch
reset for operation; Control markings legible.

8.

Ground Control Station - Main Power Selector
Switch operable; placards secure and legible; emer-
gency stop switch operates properly.

9.

Mast Assembly - Mast sections; slide pads; mast
chains; sequencing cables; platform control and
power cables (on side of mast); power cables prop-
erly tensioned and seated in sheaves; cable

sheaves rotating freely.

FILL TO LINE
on Hydraulic
Reservoir
indicates the
proper level for
hydraulic oil.

Advertising