Machine personality settings, Machine personality settings -10, Personality ranges/defaults -10 – JLG M450 ANSI Service Manual User Manual

Page 188

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

6-10

– JLG Lift –

3121127

Machine Personality Settings

NOTE: Personality settings can be adjusted within the

adjustment range in order to achieve optimum
machine performance.

Table 6-1. Personality Ranges/Defaults

FUNCTION

PERSONALITY

RANGE

DEFAULTS

DRIVE

ACCELeration

0.5s to 5.0s

1.0

DECELeration

0.1s to 2.0s

0.5

MINimum speed

0 to 25%

3

MAXimum speed

0 to 100%

100

ELEVATED MAXimum speed

0 to 25%

20

10 for CE spec E450AJ

CREEP MAXimum speed

0 to 45%

30

POSITRAC time

0 to 60s

10

POSITRAC current

50-250 A

170A

LOWER LIFT

ACCELeration

0.5 to 5.0s

1.0

DECELeration

0.0 to 3.0s

0.5

MINimum UP speed

0 to 50%

19

MAXimum UP speed

0 to 100%

95

MINimum DOWN speed

0 to 50%

7

MAXimum DOWN speed

0 to 100%

47

UPPER LIFT

ACCELeration

0.5 to 5.0

2.0

DECELeration

0.1 to 3.0

1.0

MlNimum UP speed

0 to 50

9

MAXimum UP speed

0 to 100

67

CREEP Maximum UP speed

0 to 50

30

MINimum DOWN speed

0 to 10

2

MAXimum DOWN speed

0 to 100

50

CREEP maximum DOWN speed

0 to 50

10

Advertising
This manual is related to the following products: