Diagnostic fault codes -31 – JLG M450 ANSI Service Manual User Manual

Page 209

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121127

– JLG Lift –

6-31

Table 6-8. Diagnostic Fault Codes

DTC

Flash

Code

Fault Message

Description

001

00

EVERYTHING OK

The "normal" help message in platform mode

002

00

GROUND MODE OK

The "normal" help message in ground mode

0010

00

RUNNING AT CUTBACK - OUT OF TRANSPORT POSITION

Drive speed is limited to "ELEVATED MAX" while the vehicle is
out of transport position.

0011

00

FSW OPEN

A drive or boom function has been selected but footswitch is
open.

0012

00

RUNNING AT CREEP - CREEP SWITCH OPEN

All function speeds are limited to creep because the creep
switch is open.

0013

00

RUNNING AT CREEP - TILTED AND ABOVE ELEVATION

All function speeds are limited to creep because the vehicle is
tilted and above elevation.

0032

00

PUMP MOTOR AT CURRENT LIMIT

Pump current has reached controller current limit or safe operat-
ing area limit.

0033

00

TRACTION MOTOR AT CURRENT LIMIT

Traction current has reached controller current limit or safe
operating area limit.

0034

00

DRIVING AT CREEP - TILTED

Drive speed is limited to creep because the vehicle is tilted.

211

21

POWER CYCLE

The normal help message is issued at each power cycle.

212

21

KEYSWITCH FAULTY

Both Platform and Ground modes are selected simultaneously.

213

21

FSW FAULTY

Both Footswitch Inputs are closed for more then one second.

221

22

FUNCTION PROBLEM - HORN PERMANENTL Y SELECTED

Input was CLOSED during startup

224

22

FUNCTION PROBLEM - STEER LEFT PERMANENTLY
SELECTED

The Steer Left Switch was closed during power-up.

225

22

FUNCTION PROBLEM - STEER RIGHT PERMANENTLY
SELECTED

The Steer Right Switch was closed during power-up.

227

22

STEER SWITCHES FAULTY

Both Steer Left and Steer Right inputs are closed simultane-
ously.

2211

22

FSW INTERLOCK TRIPPED

The Footswitch was closed for more then seven seconds.

2212

22

DRIVE LOCKED - JOYSTICK MOVED BEFORE FOOTSWITCH

A drive function was selected with Footswitch open.

2213

22

STEER LOCKED - SELECTED BEFORE FOOTSWITCH

A steer function was selected with Footswitch open.

2221

22

LIFT/SWING LOCKED - JOYSTICK MOVED BEFORE FOOT-
SWITCH

A lift / swing function was selected with Footswitch open.

2222

22

WAITING FOR FSW TO BE OPEN

The Footswitch was closed during Platform selection.

2245

22

FUNCTION PROBLEM - JIB SWING LEFT PERMANENTLY
SELECTED

Input was CLOSED during startup

2246

22

FUNCTION PROBLEM - JIB SWING RIGHT PERMANENTLY
SELECTED

Input was CLOSED during startup

2247

22

FUNCTION PROBLEM - PLATFORM ROTATE LEFT PERMA-
NENTLY SELECTED

Input was CLOSED during startup

2248

22

FUNCTION PROBLEM - PLATFORM ROTATE RIGHT PERMA-
NENTLY SELECTED

Input was CLOSED during startup

2249

22

FUNCTION PROBLEM - JIB LIFT UP PERMANENTLY SELECTED Input was CLOSED during startup

2250

22

FUNCTION PROBLEM - JIB LIFT DOWN PERMANENTLY
SELECTED

Input was CLOSED during startup

2251

22

FUNCTION PROBLEM - TELESCOPE IN PERMANENTLY
SELECTED

Input was CLOSED during startup