SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE

6-22

– JLG Lift –

3121213

28. Upper Master Cylinder Barrel End

Lube Point(s) - 1 Grease Fitting
Capacity - A/R
Lube - MPG
Interval - Every 3 months or 150 hrs of operation
Comments -

29. Tower Boom Lift Cylinder Rod End

Lube Point(s) - 1 Grease Fitting
Capacity - A/R
Lube - MPG
Interval - Every 3 months or 150 hrs of operation
Comments -

30. Hydraulic Oil

Lube Point(s) - Fill Cap/Drain Plug
Capacity - A/R
Lube - HO
Interval - Check daily. Change every 2 years or 1200
hours
Comments - On new machines, those recently over-
hauled, or after changing hydraulic oil, operate all sys-
tems a minimum of two complete cycles and recheck oil
level in reservoir.

31. Hydraulic Filter

Interval - Replace filter after first 50 hours of operation,
then every 6 months or 300 hours thereafter.

Advertising