3 operator maintenance, Operator maintenance -18, Lubrication specifications -18 – JLG 600A_AJ Operator Manual User Manual

Page 118

Advertising
background image

SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE

6-18

– JLG Lift –

3121615

6.3

OPERATOR MAINTENANCE

NOTE:

The following numbers correspond to those in Figure 6-6., Oper-
ator Maintenance & Lubrication Diagram - Deutz D2011L04.

LUBRICATION INTERVALS ARE BASED ON MACHINE OPERATION UNDER NORMAL
CONDITIONS. FOR MACHINES USED IN MULTI-SHIFT OPERATIONS AND/OR EXPOSED
TO HOSTILE ENVIRONMENTS OR CONDITIONS, LUBRICATION FREQUENCIES MUST BE
INCREASED ACCORDINGLY.

1.

Swing Bearing

Lube Point(s) - 1 Grease Fittings
Capacity - A/R
Lube - MPG
Interval - Every 3 months or 150 hrs of operation
Comments - Remote Access. Apply grease and rotate in 90
degree intervals until bearing is completely lubricated.

Table 6-16. Lubrication Specifications

KEY

SPECIFICATIONS

MPG

Multipurpose Grease having a minimum dripping point of 350° F (177° C). Excel-
lent water resistance and adhesive qualities, and being of extreme pressure type.
(Timken OK 40 pounds minimum.)

EPGL

Extreme Pressure Gear Lube (oil) meeting API service classification GL-5 or MIL-
Spec MIL-L-2105

HO

Hydraulic Oil. API service classification GL-3, e.g. Mobilfluid 424.

EO

Engine (crankcase) Oil. Gas - API SF, SH, SG class, MIL-L-2104. Diesel - API CC/CD
class, MIL-L-2104B/MIL-L-2104C.

Advertising