8.

A. Oil Change w/Filter - Deutz 2011

Lube Point(s) - Fill Cap/Spin-on Element
Capacity - 11 Quarts Crankcase; 5 Quarts Cooler
Lube - EO
Interval - Every Year or 1200 hours of operation
Comments - Check level daily/Change in accordance with
engine manual. Refer to Figure 6-9., Deutz 2011 Engine Dip-
stick.

B. Oil Change w/Filter - Deutz TD2.9

Lube Point(s) - Fill Cap/Spin-on Element
Capacity - 9.6 Quarts (9.0 L)
Lube - EO
Interval - Every Year or 600 hours of operation
Comments - Check level daily/Change in accordance with
engine manual.