JLG 600A_AJ Operator Manual User Manual

Page 35

Advertising
background image

SECTION 2 - USER RESPONSIBILITIES, MACHINE PREPARATION, AND INSPECTION

3121615

– JLG Lift –

2-7

c. Mark wear pad location on the fly and mid booms.

d. Telescope boom out to full extension.

e. Measure from the mark on the fly boom to the wear

pad and measure from mark on the mid boom to the
wear pad.

f.

Add These two numbers together (they should be
approximately equal) they should measure 137" to 139"
(348 to 353 cm).

Boom Angle Switch.

a. Telescope boom to full extension.

b. Lift boom up until 1000 lb. (454 kg for ANSI markets and

450 kg for CE and Australia markets) light comes on.

c. Lift boom down using auxiliary power until 500 lb. (227

kg for ANSI markets and 230 kg for CE and Australia
markets) light comes on. Boom angle must be 45
degrees to 50 degrees (place angle indicator on base
boom between boom pivot pin and lift cylinder attach
pin).

d. Lift boom up until 1000 lb. (454 kg for ANSI markets and

450 kg for CE and Australia markets) light comes on.
Boom angle should be 55 degrees to 64 degrees.

NOTE:

If limit switch settings need to be changed, you will need to
recheck that the 500 lb. (227 kg for ANSI markets and 230 kg for
CE and Australia markets) light comes on at 45 degrees to 50
degrees when lifting down.

7.

Check capacity limit switch as follows:

Main Boom Length Switch.

a. Lift main boom to approximately horizontal.

b. Telescope boom out until 500 lb. (227 kg for ANSI mar-

kets and 230 kg for CE and Australia markets) light
comes on (may need to used auxiliary power to posi-
tion boom correctly).

c. Mark the wear pad location on the main fly boom.

d. Telescope the main boom to full extension.

e. Measure from the mark on the fly boom to the wear

pad. The dimension should be 125" to 127" (317.5 to
322.5 cm).