Electrical System

9-30

G6-42A, G9-43A, G10-43A

b. Tilt/Auxiliary Calibration Menu

MENU

SUB-MENU

COMMENT

Calibrations:

Fork Tilt

Cal. Fork Tilt?

Yes: Enter, No: ESC

The technician will press the ENTER key to initiate calibration, or the
ESC key to leave menu.

Fork Tilt Roller

FWD to Max

The technician will knurl the fork tilt roller to the +AR position and
press the ENTER key to confirm.

Fork Tilt Roller

Center

The the technician will release the fork tilt roller and press the ENTER
key to confirm.

Fork Tilt Roller

REV to Max

The technician will knurl the fork tilt roller to the - AR position and
press the ENTER key to confirm.

Fork Tilt Roller

Center

The the technician will release the fork tilt roller and press the ENTER
key to confirm.

Calibrations:

Complete

The control system will display this message to advise that the
procedure was successful. The technician will press the ESC key to
leave this menu.

Calibrations:

Failed

The control system will display this message to advise that the
procedure was unsuccessful. The technician will press the ESC key to
leave this menu.

Calibrations:

Aux Hydraulic

Cal. Aux Hyd?

Yes: Enter, No: ESC

The technician will press the ENTER key to initiate calibration, or the
ESC key to leave menu.

Aux Hyd Roller

FWD to Max

The technician will knurl the auxiliary hydraulic roller to the +AR
position and press the ENTER key to confirm.

Aux Hyd Roller

Center

The the technician will release the auxiliary hydraulic roller and press
the ENTER key to confirm.

Aux Hyd Roller

REV to Max

The technician will knurl the auxiliary hydraulic roller to the - AR
position and press the ENTER key to confirm.

Aux Hyd Roller

Center

The the technician will release the auxiliary hydraulic roller and press
the ENTER key to confirm.

Calibrations:

Complete

The control system will display this message to advise that the
procedure was successful. The technician will press the ESC key to
leave this menu.

Calibrations:

Failed

The control system will display this message to advise that the
procedure was unsuccessful. The technician will press the ESC key to
leave this menu.