JLG G6-42A Service Manual User Manual

Page 191

Advertising
background image

9-35

G6-42A, G9-43A, G10-43A

Electrical System

998

Eeprom Failure -

Check All Settings

Fork Tilt Up & Down, Auxiliary Hydraulics & De-

Clutch functionality prevented

The control module detected an issue with the

non-volatile memory used to retain Personalities
and Calibrations. Verify all settings using the JLG
Analyzer.

Low-Side Fault Relay de-energized

Yes

2239

Function Problem -

Joystick Calibration Faulty

Fork Tilt Up & Down, prevented

The joystick calibration has never been performed,

is improper or calibration attempt has failed. Re-
calibrate the Fork Tilt and Auxiliary Hydraulic
(optional) joysticks to clear this fault.

Auxiliary Hydraulics prevented if Machine Setup’s

AUX HYDRAULIC is ENABLED

No

23100

Auxiliary Hydraulic Joystick -

Voltage Disagreement

Auxiliary Hydraulic A & B prevented

Analog feedback from the joystick’s auxiliary roller

did not agree within ±25% for 1000mS. Auxiliary
Hydraulics will be prevented until the next power
cycle. This fault may be caused by a joystick issue,
improper wiring or a control module issue.

Yes

259

Model Change - Hydraulics

Suspended - Cycle Ems

Fork Tilt Up & Down, Auxiliary Hydraulics & De-

Clutch functionality prevented

The user changed the Model Selection using a

JLG Analyzer. All functions are being prevented
until the EMS is cycled.

Machine Setup’s MODEL was changed via JLG

Analyzer

Yes

DTC

Event

Comment

Latched

Advertising