Electrical System

9-34

G6-42A, G9-43A, G10-43A

33198

Auxiliary Function -

A Valve - Short To Ground

The actual current is greater than 200mA, PWM is

95%, and the digital output driver’s diagnostic
feedback is low

The auxiliary hydraulic “A” digital output was

shorted to ground. This fault may be caused by
improper wiring or a control module issue.

Active when Machine Setup’s AUX HYDRAULIC is

set to ENABLED

Yes

33199

Auxiliary Function -

B Valve - Open Circuit

The desired current is greater than 250mA, but the

actual current is less then 75mA

The auxiliary hydraulic “B” digital output was open-

circuit. This fault may be caused by improper
wiring or a control module issue.

Active when Machine Setup’s AUX HYDRAULIC is

set to ENABLED

Yes

33200

Auxiliary Function -

B Valve - Short To Ground

The actual current is greater than 200mA, PWM is

95%, and the digital output driver’s diagnostic
feedback is low

The auxiliary hydraulic “B” digital output was

shorted to ground. This fault may be caused by
improper wiring or a control module issue.

Active when Machine Setup’s AUX HYDRAULIC is

set to ENABLED

Yes

441

Battery Voltage Too Low -

System Shutdown

Fork Tilt Up & Down, Auxiliary Hydraulics & De-

Clutch functionality prevented

Battery voltage is less than 8.0V so the control

module has prevented associated functionality.

No

442

Battery Voltage Too High -

System Shutdown

Fork Tilt Up & Down, Auxiliary Hydraulics & De-

Clutch functionality prevented

Battery voltage is greater than 8.0V so the control

module has prevented associated functionality.

Low-Side Fault Relay de-energized

Yes

447

Reference Voltage Out Of

Range

Fork Tilt Up & Down, Auxiliary Hydraulics & De-

Clutch functionality prevented

The control module’s +5V reference was

measured greater than 5.4V or less than 4.6V for
1000mS. Since this reference voltage supplies the
joystick(s), fork tilt and auxiliary hydraulic functions
must be prevented.

Low-Side Fault Relay de-energized