3 electrical systemengine system, 4 engine specifications, Electrical systemengine system – JLG G6-42A Service Manual User Manual

Page 28: Engine specifications

Advertising
background image

General Information and Specifications

2-16

G6-42A, G9-43A, G10-43A

2.4.3

Electrical SystemEngine System

2.4.4

Engine Specifications

Note: Engine manufacturer's maximum “high idle” setting is lockwired and sealed. DO NOT disturb this setting

Battery (if equipped for ULS)

Type, Rating

12 BCI, Negative (-) Ground, Maintenance Free

Cold Cranking Amps @ 0° F (-18° C)

950

Cranking Amps @ 32° F (-18° C)

1190

Reserve Capacity Minutes @ 25 Amps

185

Group/Series Group

31

Alternator

12V, 120 Amps

Battery (if equipped for LS)

Type, Rating

12 BCI, Negative (-) Ground, Maintenance Free

Cold Cranking Amps @ 0° F (-18° C)

700

Cranking Amps @ 32° F (-18° C)

840

Reserve Capacity Minutes @ 25 Amps

180

Group/Series Group

31

Alternator

12V, 120 Amps

Battery: Arctic if Equipped (2)

Type, Rating

12 BCI, Negative (-) Ground, Maintenance Free

Cold Cranking Amps @ 0° F (-18° C)

750

Cranking Amps @ 32° F (-18° C)

1000

Reserve Capacity Minutes @ 25 Amps

310

Description

G6-42A, G9-43A & G10-43A

If Equipped for ULS

If Equipped for LS

Engine Make/Model

Cummins QSB3.3

Cummins QSB3.3

Displacement

201 in³ (3,3 liters)

201 in³ (3,3 liters)

Low Idle

1000 rpm

1000 rpm

High Idle

2600 rpm

2600 rpm

Horsepower

100 HP (74,6 kW) @ 2600 rpm

99 HP (74 kW) @ 2600 rpm

Peak Torque

306 lb-ft (415 Nm) @ 1600 rpm

306 lb-ft (415 Nm) @ 1600 rpm

Fuel Delivery

Fuel Injection

Air Cleaner

Dry Type, Replaceable Primary and Safety Elements

Advertising
This manual is related to the following products: