9-33

G6-42A, G9-43A, G10-43A

Electrical System

33192

Fork Tilt Valve -

Short To Battery

Fork Tilt Up & Down, Auxiliary Hydraulics

functionality prevented

The fork tilt up or down digital output was shorted

to battery. Fork tilt up or down will be prevented
until the next powercycle. This fault may be caused
by improper wiring or a control module issue.

The desired current is greater than 250mA, but the

actual current is less than 75mA.

Yes

33193

Fork Tilt Up Valve -

Short To Ground

The actual current is greater than 200mA, PWM is

95%, and the digital output driver’s diagnostic
feedback is low

The fork tilt up digital output was shorted to

ground. This fault may be caused by improper
wiring or a control module issue.

Yes

33194

Fork Tilt Down Valve -

Open Circuit

The desired current is greater than 250mA, but the

actual current is less then 75mA

The fork tilt down digital output was open-circuit.

This fault may be caused by improper wiring or a
control module issue.

Yes

33195

Fork Tilt Down Valve -

Short To Ground

The actual current is greater than 200mA, PWM is

95%, and the digital output driver’s diagnostic
feedback is low

The fork tilt down digital output was shorted to

ground. This fault may be caused by improper
wiring or a control module issue.

Yes

33196

Auxiliary Function -

A Valve - Open Circuit

The desired current is greater than 250mA, but the

actual current is less then 75mA

The auxiliary hydraulic “A” or “B” digital output was

open-circuit. This fault may be caused by improper
wiring or a control module issue.

Yes

33197

Auxiliary Function -

A/B Valve - Short To Battery

Fork Tilt Up & Down, Auxiliary Hydraulics

functionality prevented

The auxiliary hydraulic “A” digital output was

shorted to battery. Auxiliary hydraulics will be
prevented until the next power cycle. This fault may
be caused by improper wiring or a control module
issue.

Active when Machine Setup’s AUX HYDRAULIC is

set to ENABLED

The desired current is 0mA and the digital output

driver’s diagnostic feedback is low

Low-Side Fault Relay de-energized

Yes

DTC

Event

Comment

Latched