JLG G6-42A Service Manual User Manual

Page 198

Advertising
background image

Electrical System

9-42

G6-42A, G9-43A, G10-43A

418

97

15

Amber/

Blinking

Water in Fuel

Indicator

Water in Fuel Indicator High—Data Valid but Above
Normal Operational Range—Least Severe Level

422

111

2

Amber

Coolant Level

Coolant Level—Data Erratic, Intermittent,
or Incorrect

428

97

3

Amber

Water in Fuel

Indicator

Water in Fuel Sensor Circuit—Voltage Above
Normal, or Shorted to High Source

429

97

4

Amber

Water in Fuel

Indicator

Water in Fuel Sensor Circuit—Voltage Below
Normal, or Shorted to Low Source

431

558

2

Amber

Pedal Low Idle

Switch

Accelerator Pedal or Lever Idle Validation Circuit—
Data Erratic, Intermittent, or Incorrect

432

558

13

Red

Pedal Low Idle

Switch

Accelerator Pedal or Lever Idle Validation Circuit—
Out of Calibration

435

100

2

Amber

Engine Oil

Pressure

Oil Pressure Sensor Circuit—Data Erratic,
Intermittent, or Incorrect

441

168

18

Amber

Electrical

Potential

(Voltage)

Battery #1 Voltage Low—Data Valid but Below
Normal Operational Range—Moderately
Severe Level

442

168

16

Amber

Electrical

Potential

(Voltage)

Battery #1 Voltage High—Data Valid but Above
Normal Operational Range—Moderately
Severe Level

449

157

0

Red

Injector

Metering Rail 1

Fuel Pressure High—Data Valid but Above Normal
Operational Range—Moderately Severe Level

451

157

3

Amber

Injector

Metering Rail 1

Injector Metering Rail #1 Pressure Sensor Circuit—
Voltage Above Normal, or Shorted to High Source

452

157

4

Amber

Injector

Metering Rail 1

Injector Metering Rail #1 Pressure Sensor Circuit—
Voltage Below Normal, or Shorted to Low Source

488

105

16

Amber

Intake Manifold

Manifold 1 Temperature—Data Valid but Above Nor-
mal Operational Range—Moderately Severe Level

489

191

18

Amber

Transmission

Output Shaft

Speed

Transmission Output Shaft Speed—Data Valid but
Below Normal Operational Range—Moderately
Severe Level

497

1377

2

Amber

Switch Circuit

Multiple Unit Synchronization Switch Circuit—Data
Erratic, Intermittent, or Incorrect

Fault

Codes

SPN

Codes

FMI

Codes

Lamp

Color

SPN

Description

Cummins Description

Advertising
This manual is related to the following products: