background image

Section 3 - Controls and Indicators

3-14

31200567

Load Stability Indicator - LSI (L2906H, 2906H & 3507H)

Before S/N 1160005989 excluding 1160005189, 1160005314 & 1160005414

The LSI (1) provides visual and audible indication of forward stability limitations
when machine is static on firm, level surface.

• Green LED (2) will illuminate when LSI power is on.

• When approaching forward stability limitations LEDs progressively illuminate,

green (3), then yellow (4) and finally red (5).

• The warning buzzer sounds as the yellow LED illuminates.

• As the telehandler reaches forward stability limitations and the red LED

illuminates, the automatic function cut-out is activated. Certain functions are
disabled (i.e. boom lift, extend, etc). Retract boom to re-enable functions.

• Test LSI (6) at the beginning of each work shift. See Section 8 - Additional

Checks.

WARNING

TIP OVER HAZARD. The LSI considers only longitudinal stability limitations,
observe all operating parameters. Failure to follow operating parameters of the
telehandler could damage the equipment and/or cause tip over.

OAH1330

1

2

3

4

5

6

Load Moment

Indicator

100

%

TEST

Advertising
This manual is related to the following products: