Table 4 – Opening dimensions -- In. (mm)

FURNACE

CASING

WIDTH

APPLICATION

PLENUM OPENING

FLOOR OPENING

A

B

C

D

14–3/16

(376)

Upflow Applications on Combustible or Noncombustible Floor-

ing (KGASB subbase not required)

12---11/16

(322)

21---5/8

(549)

13---5/16

(338)

22---1/4

(565)

Downflow Applications on Noncombustible Flooring (KGASB

subbase not required)

12---9/16

(319)

19

(483)

13---3/16

(335)

19---5/8

(498)

Downflow applications on combustible flooring (KGASB sub-

base required)

11---13/16

(284)

19

(483)

13---7/16

(341)

20---5/8

(600)

Downflow Applications on Combustible Flooring with CNPV,

CNRV, CAR, or CAP Coil Assembly or KCAKC coil box

(KGASB subbase not required)

12---5/16

(319)

19

(483)

13---5/16

(338)

20

(508)

17–1/2

(445)

Upflow Applications on Combustible or Noncombustible Floor-

ing (KGASB subbase not required)

16

(406)

21---5/8

(549)

16---5/8

(422)

22---1/4

(565)

Downflow Applications on Noncombustible Flooring (KGASB

subbase not required)

15---7/8

(403)

19

(483)

16---1/2

(419)

19---5/8

(498)

Downflow applications on combustible flooring (KGASB sub-

base required)

15---1/8

(384)

19

(483)

16---3/4

(425)

20---5/8

(600)

Downflow Applications on Combustible Flooring with CNPV,

CNRV, CAR, or CAP Coil Assembly or KCAKC coil box

(KGASB subbase not required)

15---1/2

(394)

19

(483)

16---1/2

(419)

20

(508)

21

(533)

Upflow Applications on Combustible or Noncombustible Floor-

ing (KGASB subbase not required)

19---1/2

(495)

21---5/8

(549)

20---1/8

(511)

22---1/4

(565)

Downflow Applications on Noncombustible Flooring (KGASB

subbase not required)

19---3/8

(492)

19

(483)

20

(508)

19---5/8

(498)

Downflow applications on combustible flooring (KGASB sub-

base required)

18---5/8

(473)

19

(483)

20---1/4

(514)

20---5/8

(600)

Downflow Applications on Combustible Flooring with CNPV,

CNRV, CAR, or CAP Coil Assembly or KCAKC coil box

(KGASB subbase not required)

19

(483)

19

(483)

20

(508)

20

(508)

24---1/2

(622)

Upflow Applications on Combustible or Noncombustible Floor-

ing (KGASB subbase not required)

23

(584)

21---1/8

(537)

23---5/8

(600)

22---1/4

(565)

Downflow Applications on Noncombustible Flooring (KGASB

subbase not required)

22---7/8

(581)

19

(483)

23---1/2

(597)

19---5/8

(498)

Downflow applications on Combustible flooring (KGASB sub-

base required)

22---1/8

(562)

19

(483)

23---3/4

(603)

20---5/8

(600)

Downflow Applications on Combustible Flooring with CNPV,

CNRV, CAR, or CAP Coil Assembly or KCAKC coil box

(KGASB subbase not required)

22---1/2

(572)

19

(483)

23---1/2

(597)

20

(508)

UPFLOW

DOWNFLOW

HORIZONTAL

YES

NO

NO

YES

YES

YES

NO

120

°

MIN

YES

120

°

MIN

YES

120

°

MIN

90

°

90

°

A02020

Fig. 14 -- Duct Flanges