Table 7 – Electrical Data

FURNACE

SIZE

VOLTS---

HERTZ---

PHASE

OPERATING VOLTAGE

RANGE

MAX

UNIT

AMPS

UNIT

AMPACITY#

MAXIMUM

WIRE

LENGTH

FT. (M)‡

MAXIMUM

FUSE OR

CKT BKR

AMPS†

MINIMUM

WIRE

GAUGE

MAX*

MIN.*

045---08/024045

115---60---1

127

104

5.3

7.42

49 (14.9)

15

14

045---12/036045

115---60---1

127

104

7.1

9.67

38 (11.5)

15

14

070---08/024070

115---60---1

127

104

5.2

7.22

51 (15.5)

15

14

070---12/036070

115---60---1

127

104

7.3

9.90

37 (11.2)

15

14

070---16/048070

115---60---1

127

104

10.1

13.42

27 (8.2)

15

14

090---14/042090

115---60---1

127

104

8.2

10.84

34 (10.3)

15

14

090---16/048090

115---60---1

127

104

9.9

13.0

28 (8.5)

15

14

090---20/060090

115---60---1

127

104

12.9

16.70

34 (10.3)

20

12

110---12/036110

115---60---1

127

104

8.2

10.76

34 (10.3)

15

14

110---16/048110

115---60---1

127

104

10.1

13.19

28 (8.5)

15

14

110---22/066110

115---60---1

127

104

13.7

17.60

32 (9.7)

20

12

135---16/048135

115---60---1

127

104

10.2

13.28

27 (8.2)

15

14

135---22/066135

115---60---1

127

104

14.5

18.61

30 (9.1)

20

12

155---20/060155

115---60---1

127

104

15.0

19.34

29 (8.8)

20

12

* Permissible limits of the voltage range at which the unit operates satisfactorily.
# Unit ampacity = 125% of largest operating component’s full load amps plus 100% of all other potential operating components (EAC, humidifier,
etc.) full load amps.
{

Time---delay type is recommended.

}

Length shown is as measured 1 way along wire path between unit and service panel for maximum 2% voltage drop.

U.S. Installations: Make all electrical connections in accordance
with National Electrical Code (NEC) ANSI/NFPA 70--2008 and

any local codes or ordinances that might apply.

FIRE HAZARD
Failure to follow this warning could result in personal

injury, death, or property damage.
Do not connect aluminum wire between disconnect switch

and furnace. Use only copper wire.

!

WARNING

Use a separate branch electrical circuit with a properly sized fuse

or circuit breaker for this furnace. See Table 7 for wire size and
fuse specifications. A readily accessible means of electrical

disconnect must be located within sight of the furnace.
NOTE: Proper polarity must be maintained for 115--v wiring. If
polarity is incorrect, control LED status indicator light will flash
rapidly and furnace will NOT operate.
J--BOX RELOCATION
NOTE
: If factory location of J--Box is acceptable, go to next
section (ELECTRICAL CONNECTION TO J--BOX).
NOTE: On 14” wide casing models, the J--Box shall not be
relocated to other side of furnace casing when the vent pipe is
routed within the casing.

1. Remove and save two screws holding J--Box. (See Fig. 24

.)

NOTE: The J--Box cover need not be removed from the J--Box
in order to move the J--Box. Do NOT remove green ground
screw inside J--Box.

2. Cut wire tie on loop in furnace wires attached to J--Box.
3. Move J--Box to desired location.
4. Fasten J--Box to casing with the two screws removed in

Step 1.

5. Route J--Box wires within furnace away from sharp edges,

rotating parts, and hot surfaces.

Factory

Factory
Installed

Installed

Alternate

Alternate
Location

Location

A10291

Fig. 24 -- Relocating J--Box

ELECTRICAL CONNECTION TO J--BOX

6. Reinstall cover to J--Box. Do not pinch wires between

cover and bracket.

Electrical Box on Furnace Casing Side. See Fig. 25.

FIRE OR ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal

injury, death, or property damage.
If field--supplied manual disconnect switch is to be mounted

on furnace casing side, select a location where a drill or

fastener cannot damage electrical or gas components.

!

WARNING

312AA

V

Advertising