SAFETY CONSIDERATIONS

FIRE, EXPLOSION, ELECTRICAL SHOCK, AND

CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in dangerous

operation, serious injury, death, or property damage.
Improper installation, adjustment, alteration, service,

maintenance, or use could cause carbon monoxide

poisoning, explosion, fire, electrical shock, or other

conditions which may cause personal injury or property

damage. Consult a qualified service agency, local gas

supplier, or your distributor or branch for information or

assistance. The qualified service agency must use only

factory--authorized and listed kits or accessories when

modifying this product.

!

WARNING

FURNACE RELIABILITY HAZARD
Improper installation or misapplication of furnace may

require excessive servicing or cause premature component

failure.
Application of this furnace should be indoors with special

attention given to vent sizing and material, gas input rate,

air temperature rise, unit leveling, and unit sizing.

CAUTION

!

CUT HAZARD
Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care

and wear appropriate protective clothing, safety glasses and

gloves when handling parts, and servicing furnaces.

CAUTION

!

Improper

installation,

adjustment,

alteration,

service,

maintenance, or use can cause explosion, fire, electrical shock, or
other conditions which may cause death, personal injury, or

property damage. Consult a qualified installer, service agency, or

your distributor or branch for information or assistance. The
qualified installer or agency must use factory--authorized kits or

accessories when modifying this product. Refer to the individual
instructions packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing,
and work gloves. Have a fire extinguisher available. Read these

instructions thoroughly and follow all warnings or cautions

include in literature and attached to the unit. Consult local
building codes, the current editions of the National Fuel Gas

Code (NFGC) NFPA 54/ANSI Z223.1 and the National
Electrical Code (NEC) NFPA 70.

Recognize safety information. This is the safety--alert symbol

.

When you see this symbol on the unit and in instructions or
manuals, be alert to the potential for personal injury.
Understand the signal words DANGER, WARNING, and

CAUTION. These words are used with the safety--alert symbol.

DANGER identifies the most serious hazards which will result in

severe personal injury or death. WARNING signifies hazards
which could result in personal injury or death. CAUTION is

used to identify unsafe practices which may result in minor

personal injury or product and property damage. NOTE is used
to highlight suggestions which will result in enhanced

installation, reliability, or operation.

product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability,

or operation.

1. Use only with type of gas approved for this furnace. Refer

to the furnace rating plate.

2. Install this furnace only in a location and position as spe-

cified in the “Location” section of these instructions.

3. Provide adequate combustion and ventilation air to the

furnace space as specified in “Air for Combustion and
Ventilation” section.

4. Combustion products must be discharged outdoors. Con-

nect this furnace to an approved vent system only, as spe-
cified in the “Venting” section of these instructions.

5. Never test for gas leaks with an open flame. Use a com-

mercially available soap solution made specifically for the
detection of leaks to check all connections, as specified in

the “Gas Piping” section.

6. Always install furnace to operate within the furnace’s in-

tended temperature--rise range with a duct system which
has an external static pressure within the allowable range,
as specified in the “Start--Up, Adjustments, and Safety

Check” section. See furnace rating plate.

7. When a furnace is installed so that supply ducts carry air

circulated by the furnace to areas outside the space con-
taining the furnace, the return air shall also be handled by

duct(s) sealed to the furnace casing and terminating out-
side the space containing the furnace. See “Air Ducts” sec-
tion.

8. A gas--fired furnace for installation in a residential garage

must be installed as specified in the warning box in the

“Location” section.

9. The furnace may be used for construction heat provided

that the furnace installation and operation complies with

the first CAUTION in the LOCATION section of these in-
structions.

10. These Multipoise Gas--Fired Furnaces are CSA (formerly

A.G.A. and C.G.A.) design--certified for use with natural

and propane gases (see furnace rating plate) and for install-
ation in alcoves, attics, basements, closets, utility rooms,
crawlspaces, and garages. The furnace is factory--shipped

for use with natural gas. A CSA (A.G.A. and C.G.A.) lis-
ted accessory gas conversion kit is required to convert fur-

nace for use with propane gas.

11. See Fig. 2 for required clearances to combustible construc-

tion.

12. Maintain a 1--in. (25 mm) clearance from combustible ma-

terials to supply air ductwork for a distance of 36 inches

(914 mm) horizontally from the furnace. See NFPA 90B
or local code for further requirements.

13. These furnaces SHALL NOT be installed directly on car-

peting, tile, or any other combustible material other than
wood flooring. In downflow installations, factory access-

ory floor base MUST be used when installed on combust-
ible materials and wood flooring. Special base is not re-

quired when this furnace is installed on manufacturer’s
Coil Assembly Part No. CAR, CAP, CNRV, CNPV or
when Coil Box Part No. KCAKC is used. See Fig. 2 for

clearance to combustible construction information.

INTRODUCTION

The Series 140/E 4--way multipoise Category I fan--assisted

furnace is CSA (formerly A.G.A. and C.G.A.) design--certified. A
Category I fan--assisted furnace is an appliance equipped with an

integral mechanical means to either draw or force products of
combustion through the combustion chamber and/or heat

exchanger. The furnace is factory--shipped for use with natural