312aa v – Bryant 312AAV/JAV User Manual

Page 2

Advertising
background image

2

A

A

B

[736.9]

[736.9]

29

29

Ш7/8

Ш7/8

[22.2]

[22.2]

ACCESSORY

ACCESSORY

5 15/16

5 15/16

[150.7]

[150.7]

28.39

28.39

[721.2]

[721.2]

Ш7/8

Ш7/8

[22.2]

[22.2]

ACCESSORY

ACCESSORY

14 7/8

14 7/8

[337.3]

[337.3]

(BOTH SIDES)

(BOTH SIDES)

Ш7/8

Ш7/8

[22.2]

[22.2]

ACCESSORY

ACCESSORY

Ш7/8

Ш7/8

[22.2]

[22.2]

ACCESSORY

ACCESSORY

Ш1 3/4

Ш1 3/4

[44.5]

[44.5]

GAS ENTRY

GAS ENTRY

Ш1/2

Ш1/2

[12.7]

[12.7]

THERMOSTAT WIRE ENTRY

THERMOSTAT WIRE ENTRY

22 1/16

22 1/16

[560]

[560]

SIDE INLET

SIDE INLET

(BOTH SIDES)

(BOTH SIDES)

11 7/16

11 7/16

[290.7]

[290.7]

9 11/16

9 11/16

[245.4]

[245.4]

[197.8]

[197.8]

7 13/16

7 13/16

Ш7/8

Ш7/8

[22.2]

[22.2]

J.BOX PROVISION

J.BOX PROVISION

Ш7/8

Ш7/8

[22.2]

[22.2]

JUNCTION BOX

JUNCTION BOX

LOCATION

LOCATION

Ш1 3/4

Ш1 3/4

[44.5]

[44.5]

GAS ENTRY

GAS ENTRY

1 15/16

1 15/16

[49.2]

[49.2]

1

[25.4]

[25.4]

1 1/4

1 1/4

[31.8]

[31.8]

29 9/16

29 9/16

[750.7]

[750.7]

1 15/16

1 15/16

[49.2]

[49.2]

5 5/8

5 5/8

[143.3]

[143.3]

5 7/16

5 7/16

[138.5]

[138.5]

6 13/16

6 13/16

[172.3]

[172.3]

Ш1/2

Ш1/2

[12.7]

[12.7]

THERMOSTAT WIRE ENTRY

THERMOSTAT WIRE ENTRY

19

19

[481.7]

[481.7]

OUTLET

OUTLET

D

21.6

21.6

[549.5]

[549.5]

BOTTOM INLET

BOTTOM INLET

C

33 1/4

33 1/4

[843.9]

[843.9]

9 9/16

9 9/16

[243.3]

[243.3]

3/4

3/4

[19.1]

[19.1]

5 7/8

5 7/8

[148.5]

[148.5]

3 7/16

3 7/16

[86.8]

[86.8]

9 7/8

9 7/8

[250.7]

[250.7]

27 3/4

27 3/4

[704.7]

[704.7]

2 5/16

2 5/16

[59]

[59]

FRONT OF CASINGFR

O

N

T

O

F

C

A

SI

N

G

TOP OF CASING

TOP OF CASING

4 13/16

4 13/16

[122.2]

[122.2]

27 3/4

27 3/4

[704.7]

[704.7]

5 7/8

5 7/8

[148.5]

[148.5]

8 5/8

8 5/8

[219]

[219]

5 1/2

5 1/2

[140.3]

[140.3]

8 7/16

8 7/16

[213.5]

[213.5]

FRONT OF CASINGFR

O

N

T

O

F

C

A

SI

N

G

TOP OF CASING

TOP OF CASING

6.1

6.1

[155.7]

[155.7]

2 1/16

2 1/16

[51.6]

[51.6]

5.1

5.1

[130.5]

[130.5]

1.7

1.7

[43.5]

[43.5]

Ш7/8

Ш7/8

[22.2]

[22.2]

ACCESSORY (2)

ACCESSORY (2)

AIR FLOW

AIR FLOW

AIR FLOW

AIR FLOW

BOTTOM RETURN

BOTTOM RETURN

WIDTH

WIDTH

AIR FLOW

AIR FLOW

KNOCK OUTS FOR

KNOCK OUTS FOR

VENTING(5

VENTING(5

PLACES)

PLACES)

A10290

NOTES:

1. Two additional 7/8---in. (22 mm) diameter holes are located in the top plate.

2. Minimum return---air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer’s recommendations for equivalent diameters.

a. For 800 CFM---16---in. (406 mm) round or 14 1/2 x 12---in. (368 x 305 mm) rectangle.
b. For 1200 CFM---20---in. (508 mm) round or 14 1/2 x 19 1/2---in. (368 x 495 mm) rectangle.
c. For 1600 CFM---22---in. (559 mm) round or 14 1/2 x 22 1/16---in. (368 x 560mm) rectangle.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side inlets,

a combination of 1 side and the bottom, or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM.

Fig. 1 -- Dimensional Drawing

Table 1 – Dimensions -- In. (mm)

FURNACE SIZE

A

CABINET

WIDTH

B

OUTLET WIDTH

C

TOP &

BOTTOM FLUE

COLLAR

D

BOTTOM

INLET WIDTH

VENT

CONNECTION

SIZE

SHIP WT

LB (KG)

ACCESSORY

FILTER MEDIA

CABINET

045---08/024045

14---3/16 (360)

12---9/16 (319)

9---5/16 (237)

12---11/16 (322)

4 (102)

104 (47)

16 (406)

045---12/036045

14---3/16 (360)

12---9/16 (319)

9---5/16 (237)

12---11/16 (322)

4 (102)

107 (49)

16 (406)

070---08/024070

14---3/16 (360)

12---9/16 (319)

9---5/16 (237)

12---11/16 (322)

4 (102)

111 (50)

16 (406)

070---12/036070

14---3/16 (360)

12---9/16 (319)

9---5/16 (237)

12---11/16 (322)

4 (102)

115 (52)

16 (406)

070---16/048070

17---1/2 (445)

15---7/8 (403)

11---9/16 (294)

16 (406)

4 (102)

126 (57)

16 (406)

090---14/042090

17---1/2 (445)

15---7/8 (403)

11---9/16 (294)

16 (406)

4 (102)

127 (58)

16 (406)

090---16/048090

21 (533)

19---3/8 (492)

13---5/16 (338)

19---1/2 (495)

4 (102)

140 (64)

20 (508)

090---20/060090

21 (533)

19---3/8 (492)

13---5/16 (338)

19---1/2 (495)

4 (102)

146 (66)

20 (508)

110---12/036110

17---1/2 (445)

15---7/8 (403)

11---9/16 (294)

16 (406)

4 (102)

135 (61)

16 (406)

110---16/048110

21 (533)

19---3/8 (492)

13---5/16 (338)

19---1/2 (495)

4 (102)

146 (66)

20 (508)

110---22/066110

21 (533)

19---3/8 (492)

13---5/16 (338)

19---1/2 (495)

4 (102)

152 (69)

20 (508)

135---16/048135

21 (533)

19---3/8 (492)

13---5/16 (338)

19---1/2 (495)

4 (102)

{

149 (68)

20 (508)

135---22/066135

24---1/2 (622)

22---7/8 (581)

15---1/16 (383)

23 (584)

4 (102)

{

163 (74)

24 (610)

155---20/060155

24---1/2 (622)

22---7/8 (581)

15---1/16 (383)

23 (584)

4 (102)

{

170 (77)

24 (610)

*135 and 155 size furnaces require a 5 or 6---in. (127 or 152 mm) vent. Use a vent adapter between furnace and vent stack. See Installation Instructions for

complete installation requirements.

312AA

V