47

www.2n.cz

DTMF dialling receive parameters

Receiver sensitivity

-27 dB

DTMF dialling send parameters:
Frequencies

According to Q23

Send level of lower frequency group

-10 dB to -6 dB

Send level of higher frequency group

-8 dB to -4 dB

Pulse dialling send parameters:
Pulse duration

60 ms *

Pause duration

40 ms *

Pulse dialling receive parameters:
Pulse duration

30 ms to 70ms

Pause duration

30 ms to 70ms.

FLASH send parameters

100 ms *

FLASH receive parameters

90 ms…150 ms *

* Preset values, can be changed

Modem detection parameters

min. -24 dB at 1300 Hz

Fax detection parameters

min. -24 dB at 1100 Hz

Dialling tone frequency

f = 425 +/-20 Hz

Dialling tone level

-5 dB

Nominal transmission attenuation:
Internal connection

0 …8 dB

External connection

-0.5….+1.5 dB

Interface RS232-C basic (galv. separate):
Signals

RXD, TXD

Transmission rate

9600 - 57600 bps

Insulation strength against ground

500 V