Omega 48 installation manual – 2N Omega 48 - Installation Manual v1.0 User Manual
Page 47

2N
®
- OMEGA 48
Installation manual
Installation manual
47
DTMF dialling receive parameters
Receiver sensitivity
-27 dB
DTMF dialling send parameters:
Frequencies
According to Q23
Send level of lower frequency group
-10 dB to -6 dB
Send level of higher frequency group
-8 dB to -4 dB
Pulse dialling send parameters:
Pulse duration
60 ms *
Pause duration
40 ms *
Pulse dialling receive parameters:
Pulse duration
30 ms to 70ms
Pause duration
30 ms to 70ms.
FLASH send parameters
100 ms *
FLASH receive parameters
90 ms…150 ms *
* Preset values, can be changed
Modem detection parameters
min. -24 dB at 1300 Hz
Fax detection parameters
min. -24 dB at 1100 Hz
Dialling tone frequency
f = 425 +/-20 Hz
Dialling tone level
-5 dB
Nominal transmission attenuation:
Internal connection
0 …8 dB
External connection
-0.5….+1.5 dB
Interface RS232-C basic (galv. separate):
Signals
RXD, TXD
Transmission rate
9600 - 57600 bps
Insulation strength against ground
500 V