2N Omega Lite - Installation Manual v1.9 User Manual

Page 27

Advertising
background image


27

J1

- connector for connecting to motherboard (or extender module)
(connector is secured against incorrect connection by the blanking off
of PIN 5,6,7,8).

J2

- connector for connecting ISDN line from equipment ISDN NT (end

point).

J3

- connector ISDN BUS.

J4-J5

- jumpers terminating ISDN line using terminating resistances of

100

Ω (connected – used for termination of ISDN lines under the

assumption that this ISDN line will end in this point (for example,
always for type PTP)) !!! NOTE

– under the assumption that the

terminating resistances are not already ISDN socket!!!

J6

- . company servicing reanimation connector.

J7

- . company servicing reanimation connector.

J8

- company servicing reanimation connector (SW for CPU).

J9

- company servicing reanimation connector (SW for ALTERA).


D1

- signalling LED (synchronisation of layer 1).

D2

- signalling LED (synchronisation of layer 2).

D3

- signalling LED (occupying of channel B1).

D4

- signalling LED (occupying of channel B2).


D5

- signalling LED (power of module on).

Advertising