Stopmulticastrecv, Setcamerainput, Camera input selection – 2N Helios IP Automation Manual v2.7 User Manual

Page 26: Action.stopmulticastrecv, Action.setcamerainput, Parameters, Example

Advertising
background image

26

2N TELEKOMUNIKACE a.s., www.2n.cz

®

Action.StartMulticastRecv: Chanel=1; Address=239.0.0.1; Port=10000

Action.StopMulticastRecv

The

block defines the stopping action for audio stream receiving

StopMulticastRecv

to a multicast IP address.

Parameters

Event – define the event to launch this action.
Condition – define the condition to be met for the action to be executed. This
parameter is optional.
Channel – define the channel number (1-4) to be controlled.

Example

Stop audio stream receiving via channel 1 if the event defined on row 2 arises:

Action.StopMulticastRecv: Channel=1

Action.SetCameraInput

The

block defines the action that switches the video signal sources –

SetCameraInput

either the integrated video camera or an external IP camera, or two inputs for
analogue camera connection to the 2N Helios IP Video Kit.

®

Parameters

Event – define the event to launch this action.
Condition – define the condition to be met for the action to be executed. This
parameter is optional.
Type – define the video signal type. A change during a call will apply only for this
call. Other video receivers receive video from the same source

.

Valid values:

internal – internal camera (or external analogue video camera
connected directly to the device)

external – external IP camera.

The parameter is optional, the default value is

.

internal

Id – define the video signal channel. The parameter is available with the 2N

®

Helios IP Video Kit model only and applicable only if the Type parameter is set to

.

internal

Valid values:

1 – analogue camera connected to input 1
2 – analogue camera connected to input 2

Advertising