8
HTTP request URI will be as follows: http://192.168.1.1/ABCD?Key=*
Every event defines the
and
variables.
TimeStamp
Count
TimeStamp contains encoded date and time of the last event generation in the Unix
Time format (second count from 00:00:00 1.1.1970).
Count contains the count of event generations after the device start or last block
configuration change. The variable increases by 1 after each event generation.
Refer to the following subsections for more variables with specific functions.
Tip
The Upper/Lower case is not be respected in the variable names.
Caution
You cannot use the variables in the block relation defining parameters, i.e.
Event, Condition, etc.