5. Conditions
2N Helios IP Automation
®
defines the following types of conditions:
– time profile state
– current call state
– logical AND of conditions
– always true condition
– always false condition
– RS-type flip-flop
See below for details on the conditions and their parameters and use.
Condition.ProfileState
The
block defines the condition to be met in the case of active/inactive
ProfileState
time profile.
Parameters
Profile – define the time profile number (1–20 depending on the intercom
model).
State – define the required profile state. This parameter is optional.
Valid values:
active – active profile (default value)
inactive – inactive profile.