Specifications - lpu-2428, Dimensions - in./mm – APG LPU-2428 user manual User Manual

Page 32

Advertising
background image

LPU-2428

Rev. A3, 11/08

32

Automation Products Group, Inc.

APG...Providing tailored solutions for measurement applications

Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • [email protected]

Specifications - LPU-2428

Operating Range ............................. 1 ft. to 25 ft. (0.3 m - 7.62 m)
Supply Voltage ................................ 12 to 28 VDC
Output ............................................. 4-20 mA (Max 600 ohms @ 24 VDC)

4-20 mA (Max 150 ohms @ 12 VDC)
(Includes barrier resistance)

Resolution ...................................... 0.1 in. (2.54 mm)
Accuracy ......................................... +/- 0.25% of range with no temp gradient
Sensor Adjustments ....................... Interface through RST-4001
Maximum Current Draw .................. 4-20 mA (22 mA max in Fail Safe)
Transducer Type ............................. Flat ceramic sealed PVDF face
Operating Temperature ................... -40 to 60°C
Internal Temp. Compensation ....... Yes
Sample Rate .................................... 3 sec at 4 mA - 0.6 sec at 20 mA
Beam Pattern ................................... 9° off axis
Enclosure ........................................ NEMA 4X , IP65
Cable Connection ........................... 2 terminals
Approvals ....................................... Class I, Div. 1, Groups C & D

Class I, Zone 0, AEx ia IIB, T3; IP65

Dimensions - in./mm

Advertising