DIP S2

with Art. 6333

DIP 1 DIP 2 DIP 3 DIP 4

P1

P2

A

P3

P4

P5

P6

P7

0

0

0

0

CCS

AI

A

ACT

D

PAN

K

CCP

1

0

0

0

ACT

AI

INT

INTb

D

CCS

PAN

0

1

0

0

INT

AI

INTb

ACT

CCS

CCP

D

1

1

0

0

ACT

CCS

CCP

PAN

K

D

AI

0

0

1

0

ACT

ACT

ACT

ACT

ACT

ACT

ACT

ACT

1

0

1

0

INT

ACT

A

CCS

CCP

INTb

PAN

K

0

1

1

0

AI

D

K

CCS

CCP

INTb

INT

1

1

1

0

INTb

INT

AI

INT

PAN

D

ACT

0

0

0

1

CCS

PAN

D

AI

INT

INTb

CCP

1

0

0

1

K

CCS

PAN

CCP

AI

INT

INTb

0

1

0

1

CCP

K

PAN

ACT

INT

AI

CCS

1

1

0

1

PAN

CCP

CCS

K

ACT

D

AI

0

0

1

1

D

INTb

INT

ACT

AI

CCS

CCP

1

0

1

1

INT

INT

INT

INT

INT

INT

INT

0

1

1

1

NULL

NULL

NULL

NULL

NULL

NULL

NULL

NULL

NULL

1

1

1

1

PROG

Legend

A

Lock- release

CCS

Switchboard call

INTb

Two-family intercom
- for KIT only

Speech

K

Guardian door-entry
phone call

NULL

No function

ACT

Actuator

D

Doctor

PROG

Programmed functions,
see pages 28-33
In this Dip switch setting,
the buttons control the
programmed functions; the
NON-programmed buttons
control functions referred to
on line 0000

AI

Self-ignition

PAN

Panic

CCP

Main switchboard call

INT

Programmable
intercom, general or
selective
- general internal call
as standard for KIT and
Simplebus Top

DIP S2

with Art. 6333

DIP S1

DIP 1

DIP 2

DIP 3

DIP 4

P1

P2

A

P3

P4

P5

P6

P7

ADDRESS

0

0

0

0

A

ACT

1

0

0

0

ACT

0

1

0

0

ACT

1

1

0

0

ACT

0

0

1

0

ACT

ACT

ACT

ACT

ACT

ACT

ACT

ACT

1

0

1

0

ACT

A

0

1

1

0

1

1

1

0

ACT

0

0

0

1

1

0

0

1

0

1

0

1

ACT

1

1

0

1

ACT

0

0

1

1

ACT

1

0

1

1

0

1

1

1

1

1

1

1

PROG

‰

LED1

2

LED 2

Default button settings

)FæTHEæDEFAULTæSETTINGSæSEEæTABLEæONæPAGEæ æDOæNOTæREmECTæREQUIREMENTS æ
THEæBUTTONSæCANæBEæPROGRAMMEDæDIFFERENTLYæBYæCARRYINGæOUTæTHEæSTEPSæBELOW
At the end, set S2 DIP switches 1-2-3-4 to the combination 1111
(PROG setting in the configuration tables on pages 28, 29, 30). In this
dip switch setting, the buttons control the programmed functions;

General button programming warnings

the NON-programmed buttons control functions referred to on line
0000 (see table on page 28). Restore the user code setting on S1, see
table A on page 27.

%XAMPLE
ONæAæMONITORæWITHæUSERæCODEæ æ0æPROGRAMMINGææGENERICæACTUATOR ж0жж
CODEDæACTUATORæCODEæ
æ3ETж3ж$)0æSWITCHæ æTOæTHEæCOMBINATIONæ

» LED 1 (red) flashes
æ2EFERæ TOæ THEæ TABLEæ ONæ PAGEæ æ ANDæ SELECTæ Aæ COMBINATIONæ INæ WHICHæ THEæ

ACTUATORæFUNCTIONæ!#4 æISæLISTEDæFORæTHEæBUTTONSæYOUæWISHæTOæPROGRAM

%Gæ FORæ 0æ GENERICæ ACTUATOR æ SETæ 3ж $)0ж SWITCHESæ    æ TOæ THEæ

Programming buttons for generic or coded actuator

COMBINATIONææORææORææ0!#4 æSETæ3æ$)0æSWITCHESæTOæTHEæ
COMBINATIONæ ææGOæTOæPOINTæ
%Gæ FORæ 0æ CODEDæ ACTUATORæ CODEæ  æ SETæ 3ж $)0ж SWITCHESæ    æ
TOæTHEæCOMBINATIONææORææ0!#4 æSETæ3æWITHæADDRESSææINæ
ACCORDANCEæWITHætable AæONæPAGEæ ææGOæTOæPOINTæ
æ0RESSæANDæRELEASEæTHEæBUTTONæTOæBEæASSOCIATEDæWITHæTHEæFUNCTION

»LED 2 (blue) flashes 4 times

»confirmation tone
æ4OæEXITæPROGRAMMINGæMODE æSETæ3æ$)0æSWITCHESæ æTOæTHEæCOMBINATIONæ

00

» LED 1 (red) switches off
5. When programming is complete, set S2 DIP switches 1-2-3-4 to the

combination 1111. Restore the user code setting on S1, see table A
on page 27.