10.5 Changing device configuration (using DIPswitches)

Tip!

You will find an animation on device configuration at www.mgb.EUCHNER.de.

DIPswitch

The devices can be configured using the DIPswitches. The following settings are

possible:

Ì

Changing system family (AR/AP switching)

Ì

Deactivating guard lock monitoring

Ì

Activate release monitoring (possible only with active guard lock monitoring)

Position of the switches

Item

Description

1

DIPswitch

2

Sticker with factory setting

Function of the switches

Detail

Switch

Function

A

1+2

on: Device is operated as AP system

off: Device is operated as AR system

B

3+4

on: Guard lock monitoring is deactivated

off: Guard lock monitoring is active (usually factory setting)

C

5

on: Configuration possible

off: Configuration inhibited (factory setting)

D

6

on: release monitoring is activated

off: release monitoring is deactivated (factory setting)

Changing system family (AR/AP switching)

Caution!

Malfunction due to incorrect configuration or incorrect connection.

Ì

Note that the terminal assignment assignment also changes on changing the
configuration (see section 10.7 Terminal assignment and contact descrip-
tion, page 25
).

1. Switch off power supply.
2. Set DIPswitches 1,2 and 5 as shown.

For changing from AR => AP

For changing from AP => AR

1

ON

2

3 4

5

6

1

ON

2

3 4

5

6

3. Switch the power supply on for at least 5 seconds.

¨

The change is confirmed by the illumination of the Power LED. All other LEDs

are off.

4. Switch off power supply and set DIPswitch 5 to OFF.

¨

The next time the device is started, it operates in the operating mode set.