1 typical system times, 13 system states, 1 key to symbols – EUCHNER MGB-L2-xxxAPx-xxx User Manual

Page 32: Typical system times, System states, Key to symbols

Advertising
background image

32

Operating Instructions MGB-L1...AR.-... / MGB-L2...AR.-... and MGB-L1...AP.-... / MGB-L2...AP.-...

12.1 Typical system times

Important:

The system times given are maximum values for one device.

Ready delay:
In case of AR configuration the following applies: After switching on, the unit

carries out a self-test for 8 s. The system is ready for operation only after this time.
In case of AP configuration the following applies: After switching on, the unit car-

ries out a self-test for 0.5 s. The system is ready for operation only after this time.
Switch-on time of safety outputs:
In case of AR configuration the following applies:
The max. reaction time

from the moment when the safety guard is locked to the moment when the safety

outputs switch on T

on

is 570 ms.

In case of AP configuration the following applies: The max. reaction time from the

moment when the bolt tongue is inserted to the moment when the safety outputs

switch on T

on

is 570 ms.

Simultaneity monitoring, safety inputs FI1A/FI1B: If the safety inputs have

different switching states for longer than 150 ms, the safety outputs FO1A/FO1B

will be switched off. The devices switches to fault state.
Risk time according to EN 60947-5-3:
With active guard lock monitoring the following applies: If the guard locking is

no longer effective, the safety outputs FO1A and FO1B are deactivated after a

maximum of 350 ms.
With inactive guard lock monitoring the following applies: If the bolt tongue is pulled

out of the locking module, the safety outputs FO1A and FO1B are deactivated after

a maximum of 350 ms.
Difference time: The safety outputs FO1A and FO1B switch with a slight delay in
relation to each other. They both have the ON state at the latest after a difference
time of 10 ms.

13 System states

13.1 Key to symbols

LED not illuminated

LED illuminated

10 Hz (8 s)

LED flashes for 8 seconds at 10 Hz

3 x

LED flashes three times

X

Any state

AR

AP

AR

AP

AR

DIP

OFF

ON

DIP

OFF

ON

Advertising