TORQUE TO
10FT-LBS

LocTite 242

BACK PISTON

REASSEMBLE:

1) Use a drop of LocTite 242 on the threads and assemble the two piston

halves. Tighten using a spanner wrench and torque wrench, tighten
threads to 10ft-lbs.











2) Pressure test connector to verify seal is properly seated.



FasTest, Inc. Product Warranty

FasTest, Inc. warrants its products against defects of workmanship and/or material for 12 months from
the date of the sale by FasTest, Inc. This warranty is void if the product is misused, tampered with or
used in a manner that is not in accordance with FasTest, Inc. recommendations and/or instructions.
FasTest, Inc. is not liable for consequential or other damages including, but not limited to, loss, damage,
personal injury, or any other expense directly or indirectly arising from the use of or inability to use its
products either separately or in combination with other products. ALL OTHER WARRANTIES
EXPRESSED OR IMPLIED, WHETHER ORAL OR WRITTEN, INCLUDING BUT NOT LIMITED TO
WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE
EXPRESSLY EXCLUDED.

Remedy under this warranty is limited to replacement of the product or an account credit in the amount
of the original selling price, at the option on FasTest, Inc. All allegedly defective products must be
returned prepaid transportation to FasTest, Inc. along with information describing the products
performance, unless disposition in the field is authorized in writing by FasTest, Inc.

KSxxxx Poppet Seal Replacement

RQD Valved In-Line Connector


DESCRIPTION:

Poppet Seal Replacement for Internally Valved,

RQD Connector.














Please thoroughly read the instructions to properly replace the seal. The RQD
Connector is designed to provide a safe, reliable leak-tight seal and connection when
properly maintained and operated.

The main seal is specifically designed for the application. DO NOT use any
substitute seals.

Follow the replacement instructions carefully.

DO NOT use excessive force as this may damage the connector.

Use caution when disassembling the connector.

SLEEVE ACTUATION

FEMALE NPT
TERMINATION

SLEEVE

Advertising