10.4 Troubleshooting with Error Codes (for Service Technicians)

The indicator lamp flashes to signal a specific problem area. Counting the number of short flashes after each long
flash will give the possible causes. Example

To obtain the internal data and error code for troubleshooting, you need an IR Adapter, proper connectors, and
software. The table below is a reference guide. For further information and assistance, please contact Garland
Technical Service.

: “— …. — ….” The LED gives a long flash for 0.6 seconds. Then it

gives 4 short flashes (indicated by the dots in the example). The sequence repeats unit the error is cancelled.

Error
Code

#Flashes

Reason

Things To Check

E01

1

Hardware overcurrent. Induction coil not
detected. (1)

Check cooking pan material.
Check pan placement on cooking zone.
Check wiring and connection on induction coil.

E02

2

High coil current. Software overcurrent. (1) Check cooking pan material.

E03

3

Heat sink (KK) temperature too high. (1)

Check installation/air flow (supply of cool air).
Check fan operation.

E04

4

Cook zone temperature too high. Failure
of sensor unit or sensor unit not
connected. (1)

Check sensor unit.
Pan empty.

E05

5

Rotary power switch error. Defective
potentiometer or broken cable. (1)

Check potentiometer and its wiring.

E06

6

Internal temperature too high “generator”.
(1)

Check installation/air flow (supply of cool air).

E10

10

Communication BUS error. (1)

Check all wiring.

E12

No Flash High heat sink (KK) temperature. (2)

Check installation/air flow (supply of cool air).
Check fan operation.

E20

No Flash High internal temperature. (2)

Check installation/air flow (supply of cool air).

E21

8

Heat sink (KK) temperature sensor error.
(1)

Check wiring. Check heat sink sensor.
Contact Garland.

E24

8

Board sensor error. (1)

Check temperature sensor. Contact Garland.

E29

7

Coil connection error. Empty pan detected
or sensor error. (1)

Check cooking pan. Check sensors.

E30

6

CPU temperature too high. (1)

Check installation/air flow (supply of cool air).

E41

4

Sensor 1 overheated or defect. (1)

Check cook zone (coil) sensor 1.

E42

4

Sensor 2 overheated or defect. (1)

Check cook zone (coil) sensor 2.

E43

4

Sensor 3 overheated or defect. (1)

Check cook zone (coil) sensor 3.

E44

4

Sensor 4 overheated or defect. (1)

Check cook zone (coil) sensor 4.

E45

4

Sensor 5 overheated or defect. (1)

Check cook zone (coil) sensor 5.

E46

4

Sensor 6 overheated or defect. (1)

Check cook zone (coil) sensor 6.

(1) The induction unit stops working immediately.