4.3.1.5

Installation Steps

NOTE

Please pay attention to the orientation of the unit. All the electrical connectors are located at the
front of the unit. For parallel installation of multiple RTCSmp SH DU IN units, the units can be
installed side-to-side and front-to-back. Refer to section 4.3.1.3 Parallel Installation and
Clearance
.

IMPORTANT

To protect the induction unit from water penetration, you must apply and bond the silicone

adhesive properly to create a water-tight seal. Before you begin the installation, it is very
important to use isopropyl alcohol (minimum 70%) or equivalent to clean the flange and
the counter surfaces where the silicone adhesive will be applied.

To install the built-in unit:

1. Apply silicone adhesive PACTAN (Part#: 70000015, provided with the Air Intake Kit) to:

(A) TOP-MOUNT: The top of the counter surface where the built-in frame will sit.

(B) FLUSH-MOUNT: The top of the support step where the built-in frame will sit.

2. Carefully lower the induction unit into the opening and press the frame into the silicone, allowing a

complete water tight seal between the unit and the counter.

3. Ensure the countertop and the hob(s) are leveled.

4. FLUSH-MOUNT ONLY. Apply

silicone adhesive to fill the gap
completely around between the
flange and the counter surface.
Carefully wipe up any excess
silicone.

B

A