3dimensions and technical specifications, 1 rating plate, 2 nomenclature and models – Garland SH DU IN 10000 (2x5000 / 10kW) INDUCTION BUILT-IN LINE DUAL-ZONE COOKERS User Manual

Page 7: 3 dimensions and weights, 4 electrical specifications, 5 operating conditions, 6 compliances

Advertising
background image

Dimensions and Technical Specifications

RTCSmp Induction Built-In Line Dual Zone Cookers


Part # 4532285 Rev 4 (4/29/14)

7

3

Dimensions and Technical Specifications

3.1

Rating Plate

The rating plate specifies important information such as the model number,
serial number, and electrical specifications. The rating plate is affixed to the
unit’s housing, close to the mains power connection on the unit.

3.2

Nomenclature and Models

Series

Dual Hobs

Built-In

Power (Watt)

Models

SH =
Slim Hob

DU

IN =
Built-In Line

7000 (2x 3500)
10000 (2x 5000)

SH DU IN 7000 (2x 3500 / 7kW)
SH DU IN 10000 (2x 5000 / 10kW)

3.3

Dimensions and Weights

Glass Area Only
(width x depth)

Glass-Top with Frame
(width x depth)

Shipping
Weight

Net
Weight

7kW Model

12.60” x 22.83” (320 x 580 mm)

15.12” x 25.35” (384 x 644 mm) 25kg/55.1lb 23kg/50.7lb

10kW Model

12.60” x 22.83” (320 x 580 mm)

15.12” x 25.35” (384 x 644 mm) 27kg/59.5lb 25kg/55.1lb

3.4

Electrical Specifications

Voltage

Power

Conductor Size

7kW Model

208 V AC / 3Ph / 60Hz

7000 W (2x 3500W) / 22A

AWG 10

400 V AC / 3Ph / 50Hz

7000 W (2x 3500W) / 11A

1.5mm

2

440 V AC / 3Ph / 50Hz

7000 W (2x 3500W) / 10A

1.5mm

2

10kW Model

208 V AC / 3Ph / 60Hz

10000 W (2x 5000W) / 30A

AWG 8

400 V AC / 3Ph / 50Hz

10000 W (2x 5000W) / 16A

2.5mm

2

440 V AC / 3Ph / 50Hz

10000 W (2x 5000W) / 15A

2.5mm

2

3.5

Operating Conditions

Max. Tolerance of Nominal Supply Voltage

+6 /-10 %

Supply frequency

50/60 Hz

Ingress Protection class

IP X0

Minimal Diameter of Induction Pan

5” (12cm)

Maximum Ambient Temperature

In Storage > -4°F to +158°F (-20°C to +70°C)

In Operation >+ 41°F to +104°F (+5°C to +40°C)

Maximum Relative Air Humidity

In Storage > 10% to 90%

In Operation > 30% to 90%

Clearance from Materials

Min. 1.18” / 30mm

Maximum air flow: 70.63cfm/120m

3

per hour and min. opening: 10.075in

2

/6500mm

2

is required.

3.6

Compliances

North American models:

ETL listed in compliance with UL 197, CSA C22.2 No.109, NSF-4. Complies with FCC part 18, ICES-001

CE models comply with the latest European Norms:

EN 60335-1, EN 60335-2-36, EN 62233 (EMC/EMV)