4 no pan no heat, 5 when unit is not in use – Garland SH DU IN 10000 (2x5000 / 10kW) INDUCTION BUILT-IN LINE DUAL-ZONE COOKERS User Manual

Page 19

Advertising
background image

Operating Instructions

RTCSmp Induction Built-In Line Dual Zone Cookers


Part # 4532285 Rev 4 (4/29/14)

19

The following Power Diagram indicates that when you increase the power level, the power output does not
increase linearly. The difference in power output between two higher power levels is much larger than that
between two lower power levels.

6.4

No Pan No Heat

Energy is transferred to cookware when the induction system detects a suitable pan on the heating area. The
green indicator light signals to communicate the Pan Detection process:

 When the unit is ON without any pan on the glass-top, the green indicator light flashes; the unit is in pan

detection mode.

 As soon as an induction pan is put on the glass-top, the heating process is engaged and the indicator

light stops flashing and remains bright. However, the indicator light will keep flashing if the unit is not
detecting any pan or an unsuitable pan is placed on the glass-top.

 When you remove the pan from the heating area, power transfer to the pan is stopped immediately.

NOTE: Pan with a bottom diameter smaller than 5”(12 cm) is not detected by the system.

6.5

When Unit is Not In Use

Best Practice: If the induction unit is not in use, ensure the control knob is in the 0 (OFF) position.

 Switch the unit OFF if you take the cookware away for a while. This will prevent the heating process to

start automatically and unintentionally when a pan is placed back on the heating area. If any person
needs to use the induction unit, he/she will have to turn the unit ON intentionally.

POWER

OUTPUT

P O W E R D I A G R A M

0

1

2

3

4

5

6

7

8

9

10

11

12

P O W E R LEVEL

100%

50%

10%

20%

30%

40%

60%

70%

80%

90%

Advertising