Installation

RTCSmp

Induction

Built-In Line Dual Zone Cookers


Part # 4532285 Rev 4 (4/29/14)

9

 It is highly recommended that an exhaust fan be installed into the cabinet at an appropriate location.

This will force hot air out the cabinet and away from the induction unit. Consult an electrical or
installation expert for the most appropriate location to install a cabinet exhaust fan.

4.3

Dimensions and Installation

4.3.1

Built-In Induction Unit Installation

4.3.1.1

Dimensions: Dual Zone RTCSmp Built-In SH DU IN 7kW / 10kW

4.3.1.2

Top-Mount / Flush-Mount and Dimensions

There are two methods to install the built-in unit—top-mount (A) or flush-mount (B). The counter surface cut-out
dimensions are different for these two methods.

TOP-MOUNT — cut-out dimensions on the
counter surface:
345 x 605mm [13.58” x 23.82”]

FLUSH-MOUNT — cut-out dimensions:

(i)

Opening for flange:
minimum– 384.5 x 644.5mm [15.14 “ x 25.37”]
maximum– 385.6 x 645.6mm [15.18” x 25.41”]

(ii)

Depth for flange: 2mm [0.079”]

(iii)

Body clearance: 345 x 605mm [13.58” x 23.82”]

FRONT

FRONT

B

A

i

ii

iii