Connect rs232 control, Connect tcp/ip (ethernet) control, Connect ethernet (web browser) control – Intelix DL-HDM44 User Manual

Page 12

Advertising
background image

DL-HDM44 Installation Guide

12

Connect RS232 Control

The RS232 control port requires a standard straight-through serial cable for operation. The default settings for

the RS232 port are:

• 19200 baud

• 8 Data Bits

• 1 Stop Bit

• Parity = none

See page 19 for all available control commands for the DL-HDM44.

Connect a standard straight-through serial cable with DE9

connector between the RS232 port on the DL-HDM44 and

the controller.

Connect Ethernet (Web Browser) Control

The DL-HDM44 may be controlled via Ethernet through a web browser interface.

The TCP/IP port requires a standard straight-through Category

5 or greater cable with the TIA/EIA-568B crimp pattern for

optimal operation.

The default settings for the TCP/IP port are:

IP address: 192.168.0.178

TIA/EIA-568B

Orange/White

Orange

Green/White

Blue

Blue/White

Green

Brown/White

Brown

Pin 1

Pin 2

Pin 3

Pin 4

Pin 5

Pin 6

Pin 7

Pin 8

1

8

Connect the Ethernet cable between to the matrix and a router

with a straight-through cable or between the matrix and a

computer with a crossover cable.