Rs232 commands, Routing commands, System commands – Intelix DL-HDM44 User Manual
Page 19

DL-HDM44 Installation Guide
19
Routing Commands
RS232 Commands
RS232 Settings: 19200 baud, 8 Data bits, 1 Stop bit, Parity = None
x
= Input Number (input 2 would be 2)
y
= Output Letter (output C would be C and must be in caps)
<CR>
= Carriage return (Hex 0D)
<SP>
= Space (Hex 20)
A carriage return is required at the end of all command strings. Any changes made to the matrix via front panel,
IR, or web browser will be replied on the RS232 port.
Control via IP is not available on the DL-HDM44�
Description
Command
Response
Route input x to output y
yx
<CR>
yx
<CR>
Route input x to all outputs
ABCDx<CR>
ABCDx<CR>
Route input x to multiple outputs y
Number of outputs is unlimited
yyx
<CR>
yyx
<CR>
Reset AV routes to A1, B2, C3, D4
RS<CR>
RS<CR>
ABCD2<CR>
Route Video and Audio from input 2 to all outputs
C4<CR>
Route Video and Audio from input 4 to output C
BD3<CR>
Route Video and Audio from input 3 to outputs B and D
Examples:
System Commands
Description
Command
Response
Power full ON
P1<CR>
P1<CR>
Power off (Standby Mode)
P0<CR>
P0<CR>
Get firmware version and matrix state
ST<CR>
ST<CR>
<CR>
<CR><LF>
DL-HDM44<CR>
<CR><LF>
F/W Ver : v1.0E<CR>
<CR><LF>
Power : On<CR>
<CR><LF>
EDID : STD<CR>
<CR><LF>
Port : A1B2C3D4<CR>
Display all RS232 commands
?<CR>
Outputs list of all commands