19

Routing Commands

RS232 Commands

RS232 Settings: 19200 baud, 8 Data bits, 1 Stop bit, Parity = None

x

= Input Number (input 2 would be 2)

y

= Output Letter (output C would be C and must be in caps)

<CR>

= Carriage return (Hex 0D)

<SP>

= Space (Hex 20)

A carriage return is required at the end of all command strings. Any changes made to the matrix via front panel,

IR, or web browser will be replied on the RS232 port.

Control via IP is not available on the DL-HDM44�

Description

Command

Response

Route input x to output y

yx

<CR>

yx

<CR>

Route input x to all outputs

ABCDx<CR>

ABCDx<CR>

Route input x to multiple outputs y

Number of outputs is unlimited

yyx

<CR>

yyx

<CR>

Reset AV routes to A1, B2, C3, D4

RS<CR>

RS<CR>

ABCD2<CR>

Route Video and Audio from input 2 to all outputs

C4<CR>

Route Video and Audio from input 4 to output C

BD3<CR>

Route Video and Audio from input 3 to outputs B and D

Examples:

System Commands

Description

Command

Response

Power full ON

P1<CR>

P1<CR>

Power off (Standby Mode)

P0<CR>

P0<CR>

Get firmware version and matrix state

ST<CR>

ST<CR>

<CR>

<CR><LF>

DL-HDM44<CR>

<CR><LF>

F/W Ver : v1.0E<CR>

<CR><LF>

Power : On<CR>

<CR><LF>

EDID : STD<CR>

<CR><LF>

Port : A1B2C3D4<CR>

Display all RS232 commands

?<CR>

Outputs list of all commands