Connect audio outputs connect ir control – Intelix FLX-44 User Manual

Page 12

Advertising
background image

FLX-44 Installation Guide

12

Connect Audio Outputs

Connect IR Control

If the analog audio outputs are to be used in the installation, connect

the Left, Right, and ground reference wires to the removable 3-pole

terminal block.

Insert the removable 3-pole terminal block to the appropriate

output zone terminal.

L

R

L+
L-

R-
R+

Source Device and Matrix Control via Remote IR

Attach the plastic end of the DIGIB-EMT to the IR receiver of the

source device. Insert the TS 3.5 mm plug of the DIGIB-EMT to the IR

output port (IR OUT) of the matrix for the source device to control.

The FLX-44 has an advanced bidirectional IR control protocol through the HDBaseT output port, which allows for

the control of the sources, displays, and matrix. Intelix recommends using the DIGI-HD60C-R for installations which

require IR extension.

Only use DIGIB-EMT (IR transmitter) and DIGIB-EYE (IR receiver), which are sold separately, with the FLX-44. Third

party 12V DC IR components are not compatible with the FLX-44.

An IR signal passed from the display location through the HDBaseT connection can provide control of the source

device. The IR signal from the remote display location can also control the switching of the matrix.